20
10.1.4
Setting the stroke and fixed stop
NOTICE
Non-compliance may result in material damage.
If the stroke is reduced too much, the product and mounting piece are loaded with the residual energy.
►
Make sure that the stroke is sufficient for the complete absorption of the energy of the impact.
NOTICE
Malfunction in case of non-compliance
Make sure that a hub limit of < 50% relative to the maximum stroke is maintained.
Ö
This will avoid worsened return behavior of the piston rod.
NOTICE
Non-compliance may result in material damage.
If the integrated fixed stop of the product is used in continuous operation, this can reduce the service life.
►
In continuous operation, use an external fixed stop.
Ö
This reduces the product load.
The following product variants have an integrated fixed stop. Here, the bottom of the head moves to the fixed stop of the
product.
In the Short piston rod no head variant, the braked component sits on the fixed stop after the maximum stroke has been
reached. This takes place under consideration of the maximum forces specified in the catalog.
Short piston rod no head (D)
Steel head (S)
#P01#B7100#FA#
Plastic head (K)
INFORMATION
►
Use an external fixed stop to set the damping stroke.
Ö
As a result, the energy absorption of the product is limited to the necessary stroke. Under some circum-
stances, this can save time compared to the full stroke.
External fixed stops for the version without bellows using accessories:
• Stop sleeve
• Sensor stop sleeve
External fixed stops using the mounting piece:
• Embedding in the mounting piece
• Adjusting a stop screw
Zimmer GmbH • Im Salmenkopf 5 •
77866 Rheinau, Germany •
+49 7844 9138 0 • www.zimmer-group.com
INSTALLATION AND OPERATING INSTRUCTIONS:
PowerStop
DDOC00335 / b
EN / 2023-08-07
Содержание PowerStop PHE16X10LSAK-A
Страница 2: ......