Fault Diagnostics
1. Troubleshooting
PROBLEM
CONDITION
CAUSE
CORRECTIVE
MEASSURE
1. Compressor Unusual sound Noise at the
input
Noise at the
output
- Insufficient lubrication
- Add
- Belt tension released
- Adjust
- Loose console
- Tighten the screws
- Clutch defect
- Check
Abnormal
speed
Input cause
- Damaged parts
- Check, replace
- Clutch slipping
- Check, replace
- No lubricant
- Add
Output cause
- Belt tension released
- Adjust
Refrigerant or
oil leakage
Refrigerant or oil
leakage
- Sealing washer damaged
- Replace
- Loose head screws
- Tighten the screws
- O-Ring damaged
- Replace
Excessive
pressure
Low, high
pressure
- Clogged radiator
- Clean
- Compressor
- Replace
2. Fan
Low pressure
or not working
The fan is
running normally
- Air supply clogged
- Clean
- Freezing evaporator
- Minimum pressure
setting
- Fan switch damaged
- Replace the switch
- Compressor
- Replace
The fan is
running
abnormally
- Engine fault
- Replace
- Broken wire
- Replace
- Air leak
- Pipe leak
- Check, tighten
Fan cannot be
controlled
Engine
- Control switch fault
- Check
The engine is
running
abnormally
- Engine fault
- Replace
CABIN SYSTEM
95
Содержание COMPAX CL Series
Страница 1: ...OPERATOR S MANUAL COMPAX CL 1 2020 35 Tractor is Zetor Since 1946 40...
Страница 3: ...2...
Страница 9: ...NOTES 8...
Страница 11: ...NOTES 10...
Страница 43: ...NOTES 42...
Страница 71: ...NOTES 70...
Страница 105: ...NOTES 104...
Страница 112: ...111...
Страница 114: ...www zetor com zetor zetor com Made in EU...