User Definable Faders
Page 130
Frog 2 Operating Manual – Issue 4.3
UDF Controls …
This option in the UDF Setup Window allows you to select which attributes (colour,
beamshape, position and effects) are controlled by the physical position of the fader,
rather than being triggered at the LTP trigger level and then fading according to their
programmed fade times. This option applies to
Channel Data
and
Cue
UDF’s only.
Press the [UDF Controls …] button in the UDF Setup Window. A separate popup window
is displayed allowing you to select which of the attributes are to be controlled by the fader.
Each of the attribute buttons (Colour, Beamshape etc.) is independent and when pressed
toggles between selected and not selected. The ‘light’ in the button is lit when the attribute
is selected.
Notes –UDF Controls … (Fade CBPE) Operation
In the UDF Setup Window, there are four attribute options which may be selected or
deselected independently as required.
Moving the UDF up crossfades the attribute types which are selected relative to the fader
position, instead of using the trigger point and corresponding fade time. Any Intensity
channels which are programmed into the UDF data will always be controlled by the level of
the fader.
Therefore, if you program a UDF with colour, beamshape and position data, but set the
UDF Controls to Position and Colour, the following will happen.
When the UDF is raised - At the Trigger Level, the Beamshape parameters will crossfade
in their programmed time(s). As the fader travels upwards, the programmed position and
colour channels will crossfade to their programmed values, relative to the level of the fader
(eg at 50%, the position and colour channels will be 50% of the way between their old
values and the ones programmed into the submaster).
When the UDF is lowered - As the fader travels downwards, the programmed position and
colour channels will crossfade from their programmed value, relative to the level of the
fader (eg at 50%, the position and colour chanels are half way between the value on the
sub and the one which the value previously came from). When the fader reaches 0%, the
non-Fader Controlled channels (in this case, Beamshape), will be released and return to
their previous source or default value if no other source exists.
Содержание FROG 2
Страница 1: ...FROG 2 OPERATING MANUAL...
Страница 2: ......
Страница 76: ...Setup Page 76 Frog 2 Operating Manual Issue 4 3...
Страница 80: ...Groups Page 80 Frog 2 Operating Manual Issue 4 3...
Страница 144: ...Palettes Page 144 Frog 2 Operating Manual Issue 4 3...
Страница 152: ...Effects Page 152 Frog 2 Operating Manual Issue 4 3...
Страница 178: ...Technical Specification Page 178 Frog 2 Operating Manual Issue 4 3...
Страница 183: ......