ZEP SYSTEM I INSTALLATION MANUAL
Copyright © 2012 Zep Solar, Inc.
PAGE 10 OF 50
2.1 - General Safety
• All installations must be performed in compliance with all applicable regional and local
codes, such as the latest National Electric Code (USA), Canadian Electric Code (Canada) or
other national or international electrical standards.
• Follow all safety precautions contained in both this Installation Manual and the module
installation manual.
• Always comply with all applicable OSHA or equivalent safety standards including but not
limited to the proper use of regulation fall-protection equipment.
• Do not perform any installations in wet or windy conditions.
2.2 - Installation Safety
• The installation must conform to the details on the Project Assessment Package and Design
Guidelines provided by Zep Solar, Inc.
• All installation and servicing must be performed by qualified personnel. The installer is
responsible for ensuring that all personnel are properly trained and licensed.
• The installer is responsible for knowing and following all applicable codes and regulations
and for obtaining all required permits and inspections.
• Check applicable building codes or consult with a structural engineer to ensure that the
structure upon which the Zep System is being installed can properly support the array under
live load conditions.
• The Zep System I must be installed over an appropriately rated fire resistant roof covering.
• The Cam Feet and Interlocks must be fully engaged with both the PV modules and Spanner
Bars. You will feel a snap when Cam Feet are properly installed.
• Always use appropriate personal protective equipment (PPE) such as safety glasses, gloves,
hard hat, etc. as needed and as required by OSHA or other equivalent safety standards.
• Never expose the PV modules to excessive loads or deformation such as twisting or bending.
• Some components may be heavy and/or bulky. Always use proper lifting and carrying tech-
niques when handling components and materials at the job site.
• The installation process involves working around high-voltage electrical equipment. Follow
applicable safety regulations and best practices to avoid creating an electrocution hazard.
• The installation process requires working on roofs. Follow applicable safety regulations and
best practices to avoid a fall. Use caution to prevent objects from falling or dropping off the
roof area. Cordon off ground areas directly below roof-related work when possible.
Содержание Zep System I
Страница 1: ...VERSION 1 4 ...
Страница 12: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2012 Zep Solar Inc PAGE 8 OF 50 This page intentionally left blank ...
Страница 32: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2012 Zep Solar Inc PAGE 28 OF 50 This page intentionally left blank ...
Страница 40: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2012 Zep Solar Inc PAGE 36 OF 50 This page intentionally left blank ...
Страница 50: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2012 Zep Solar Inc PAGE 46 OF 50 This page intentionally left blank ...
Страница 54: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2012 Zep Solar Inc PAGE 50 OF 50 This page intentionally left blank ...
Страница 55: ...ZEP SYSTEM I INSTALLATION MANUAL Copyright 2011 Zep Solar Inc This page intentionally left blank ...