Any “Climate Specific Page” includes the THERMOSTAT
functionality to choose by parameter whether to include this
feature or not.
THERMOSTAT
Æ
Select the type of control to carry out:
•
Only Heat
•
Only Cool
•
Heat & Cool
REFERENCE TEMPERATURE
Æ
For every enabled
thermostat in the Z38i, users will be asked by parameter whether to
use the internal sensor measure as a reference, or if on the other
hand an external sensor will be used. The same parameterization
field offers also the possibility to choose a proportion between both
measures (Z38i internal external sensor).
Proportion
Z38i Internal Sensor
External Sensor
1 75% 25%
2 50% 50%
3 25% 75%
The resulting measure is exclusively used by the thermostat in the
Z38i, and cannot be shown through any available Communication
object.
FREEZING PROTECTION
Æ
Regardless of the status the
thermostat may be (On/Off), when “Freezing Protection” is
Climate
Page
set
for
Air
Conditioning
Control
Climate
Page
set
for
Air
Conditioning
control
with
Thermostat
included