ALARM TRIGGER VALUE
Æ
Choose whether it will be a (“0” or
“1”); this will mainly depend on the warning device installed.
CYCLICAL MONITORING
Æ
The state of the detection devices
will be cyclically monitored by enabling this parameter.
CYCLE
Æ
Defines a particular interval of time to monitor the BUS
looking for Technical Alarms or a detection device failure (in minutes).
Note
:
When an error or accident is detected on the KNX installation, InZennio
Z38i will show the “Technical Alarms Screen”, and a danger icon will appear
in the box affected; at the same time, the Panel blinks and emits a “beep” to
warn the user.
Once the warning reception is confirmed by the user (pressing the OK button),
the screen will recover its normal state:
After 90 seconds, Inzennio Z38i display will again show the “Home” default
screen.
It is
Really Importan
t to know that confirming a warning does not make the
Danger icon disappear from the box affected; this icon will only disappear from
the screen when the detector device sends again to the BUS its “normal status”;
if cyclical monitoring is enabled, it will be the own device which sends this
status when danger disappears.
2.2.4.
CONFIGURATION
This is a specific page where to adjust some basic parameters.
Every “enabled” Box in the display has a field “Name”:
NAME
Æ
This field allows a user to associate a name with the
corresponding box in the display, (11 free characters are available to set
the name).
BOX 1 (Programming Mode)
When programming a device physical address, users can set the
“Programming Mode
” directly from this box. This characteristic
makes this process easier as the user won’t need to access the rear
side of the panel to push the “Programming Button” any more
BOX 2 (Time Setting)
To set the time on the display:
¾
Time (together with the room temperature) is always displayed
in the middle upper section of the display.