![Zenith ZeDrive Скачать руководство пользователя страница 53](http://html1.mh-extra.com/html/zenith/zedrive/zedrive_user-manual_3383905053.webp)
Page 52
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
M51
Entry Error
Read Only
Units:
Range:
0
No Error
1
Invalid Code
2
Above Maximum Value
3
Below Minimum Value
4
Keypad Lockout
5
Entry Timeout
M52
Alarm Status
Read Only
Units:
Range:
1
Low Limit
2
High Limit
3
Low Alarm
4
High Alarm
5
Error Alarm 1
6
Error Alarm 2
7
Current Limit
M53
Control State
Read Only
Units:
Range:
1
JOG
32
RUN
64
Ramped Stop
128
Fast Stop
M54
Control Mode
Read Only
Units:
Range:
Bit 7
Primary (1) / Secondary (0) Data Set
Bit 6
Not used (was the forward /reverse flag on ZeTrol)
Bit 5
Closed-Loop (1) / Open-Loop (0)
Bit 4
Primary Setpoint 1 (1) / Primary Setpoint 2 (0)
Bit 3
Secondary Setpoint 3 (1) / Secondary Setpoint 4 (0)
Bit 2
Local (1) / Remote Serial (0) Control
Bit 1
Keypad Enable (1) / Disable (0)
Bit 0
Ramp Enable (1) / Disable (0)
It shows the status of control state of the controller.
It indicates the status of the optional switch inputs to the
controller. It is a single-byte with meanings assigned to
individual bits. This code, along with Code 53, is
intended for use by computer interface.
It shows the last error encountered on a keypad entry. If
any entry is not accepted by the controller, the reason
shows up here.
It shows the status of limits and alarms in the controller.
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...