ZENITH PUMPS
3. Connect Feedback Signal Cable
Magnetic pickup or hall effect sensor is usu-
ally located between motor and reducer.
Encoder is usually located at the rear of mo-
tor.
NOTE:
WHEN USING A HALL EFFECT SENSOR OR
ENCODER IN A HAZARDOUS ATMOS-
PHERE, THE OPTIONAL INTRINSICALLY
SAFE BARRIER MUST BE USED.
Field Wiring (cont’d)
+12VDC
Feedback Signal
Common
Ground
Hall Effect Sensor
Wire Color
Function
Connect To
Red
+12VDC TB2-1
White/Clear
Feedback Signal
TB2-2
Black
Common
TB2-3
Bare
Shielding
TB2-4
Encoders
Wire Color
Function
Connect To
Red
+12VDC TB2-1
White/Clear
Feedback Signal
TB2-2
Black
Common
TB2-3
Bare
Shielding
TB2-4
Explosion Proof
Magnetic Pickup
Wire Color
Function
Connect To
White
Feedback Signal
TB2-2
Black
Common
TB2-3
Green
Shielding
TB2-4
Non-Explosion Proof
Magnetic Pickup
Wire Color
Function
Connect To
White/Clear
Feedback Signal
TB2-2
Black
Common
TB2-3
Bare
Shielding
TB2-4
Optional Safety Barrier
+12VDC
Feedback Signal
Common
Ground
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...