Page 31
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
Master/Follower System
1. Preliminary Action:
•
Two individual ZeDrive systems are needed for forming
a master/follower system
•
The following is only one example. For more detailed
system integration and configuration, please refer to
Chapter 5 in “ZeDrive and ZeTrol Manual”
•
Master Reducer Gear Ratio — R
m
. If the pump is directly
coupled with the motor, the gear ratio R
m
=1
•
Follower Reducer Gear Ratio — R
f
. If the pump is di-
rectly coupled with the motor, the gear ratio R
f
=1
•
Motor maximum speed — V
M
(RPM), usually, 1800
(RPM)
•
Master Pump Capacity — C
m
(cc/rev)
•
Follower Pump Capacity — C
f
(cc/rev)
•
Master Feedback Sensor Resolution — F
m
(No. of Teeth)
•
Follower Feedback Sensor Resolution — F
f
(No. of Teeth)
2. Calculation:
2.1 Master Primary Setpoint — P
m
(cc/min)
P
m
(cc/min) = V
M
(RPM) / R
m
× C
m
(cc/rev)
2.2 Maximum Percent between Follower and Master — P
f
(%)
P
f
(%) = Follower Max. Flowrate (cc/min) / Master Max. Flowrate (cc/min)
= [ V
M
(RPM) / R
f
× C
f
(cc/rev) ] / [ V
M
(RPM) / R
m
× C
m
(cc/rev) ]
= [ R
m
/ R
f
] × [ C
f
/ C
m
]
3. Coding:
Check and change the following codes
For Master
For Follower
Primary Setpoint, Eng. Unit
Code 20 = P
m
Code 20 = P
f
Primary Display, Eng. Unit
Code 22 = P
m
Code 22 = P
f
External Ref. Resolution, PPR
Code 30 = F
m
Feedback Resolution, PPR
Code 31 = F
m
Code 31 = F
f
Primary Max. External Ref. Speed, RPM
Code 33 = V
M
Primary Max. Feedback Speed, RPM Code 34 = V
M
Code 34 = V
M
Primary Scaling Format
Code 61 = 1 (Master) Code 61 = 2 (Follower)
Primary Display Format
Code 63 = 1 (Master) Code 63 = 2 (Follower)
Analog I/O Board
(Not this jumper)
Heat Sink
Transformer
Jumper 1
(Feedback)
Feedback Jumper Location
3-wire Sensor (default):
Left
2-wire Sensor:
Left
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...