![Zenith ZeDrive Скачать руководство пользователя страница 12](http://html1.mh-extra.com/html/zenith/zedrive/zedrive_user-manual_3383905012.webp)
Page 11
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
2. Connect DC Motor Cable
•
Permanent Magnet DC Motors
Permanent magnet motor has only
two motor connections for its arma-
ture. The connections may be la-
beled A1 and A2, or may be color
coded. Select the right motor from
the connection diagrams below.
NOTE:
−
Always refer to pump drawing
for correct pump rotation. To
change rotation, reverse A1 and A2 connections
−
The motor connections shown above will produce a counter-clockwise rotation
at the reducer output shaft, viewed from the pump end (as opposed to the motor
end). This rotation should be correct for most applications. If the rotation is in-
correct, reverse A1 and A2 connections
−
If the motor in use has a thermostat, it may be connected to TB2-5 and TB2-6,
after removing the jumper
Field Wiring (cont’d)
1/4, 1/2 HP TENV & Sealed
Tight (Wash Down) Motors
(Motor End Cover Removed)
A1 A2
To Ground
1/2 HP Explosion Proof
Motors
Green — Ground
Black — A2
White — A1
Both Red — Ther-
mostat Wires
1 & 2 HP Wash Down
Motors
Red — A1
Black — A2
1 HP TEFC Motors
2 HP TEFC Motors
Black/White
— A1
Black — A2
A1 A2
Motor A2
Motor A1
Motor
Thermostat
Wires
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...