Page 43
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
Fault Code List
Code
Fault Description
Corrective Actions
10
LIMIT alarm LED lights up
This parameter establishes the minimum level of motor
RPM during operation. It is allowable to program a set-
point which is below this value, however the controller
will enforce this minimum speed (measured at the motor
shaft)
11
LIMIT alarm LED lights up
This parameter establishes the maximum level of motor
RPM during operation. It is allowable to program a set-
point which is above this value, however the controller
will enforce this maximum speed (measured at the motor
shaft)
12
LIMIT alarm LED lights up
This parameter establishes the point at which the LO-
ALARM output is turned on
13
LIMIT alarm LED lights up
This parameter establishes the point at which the HI-
ALARM output is turned on
14
Deviation alarm LED lights
up
Ramped Error Alarm establishes the error band (defined
as ramped motor speed minus actual motor speed) at
which DEV ALARM output is turned on. If the difference
between actual motor speed and ramped desired motor
speed is greater than or equal to C-14, the alarm is
turned on.
15
Deviation alarm LED lights
up
Scaled Error Alarm establishes the error band (defined
as final motor speed minus actual motor speed) at which
DEV ALARM output is turned on. If the difference be-
tween actual motor speed and final desired motor speed
is greater than or equal to C-15, the alarm is turned on
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...