![Zenith ZeDrive Скачать руководство пользователя страница 33](http://html1.mh-extra.com/html/zenith/zedrive/zedrive_user-manual_3383905033.webp)
Page 32
TO GET ASSISTANCE, CALL: 919-774-7667
ZENITH PUMPS
Master/Follower System (cont’d)
4. Wiring:
•
Make sure the feedback jumper settings are correct and matched to the feedback sensors of
master and follower systems
Master
Follower
Jumper Settings
3-wire
3-wire left
3-wire
2-wire left
2-wire
2-wire left
2-wire
3-wire left
NOTE: Do not count bare wire (shield wire)
•
Connect wires like the following illustration to form a master/follower system (for detailed
connection, please refer to page G-4 in “ZeDrive and ZeTrol Manual”
Follower ZeDrive
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Red
(for 3-wire)
Wht
Bare
(Shield)
Blk
To
Feedback
Sensor
Jumpers
To AC
Power
To Follower Motor
To Follower
Feedback
Sensor
2
3
A2
A1
L1
N
G
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
Red
(for 3-wire)
Wht
Bare
(Shield)
Blk
To
Feedback
Sensor
Jumpers
To Master Motor
To AC
Power
Master ZeDrive
To Master
Feedback
Sensor
Содержание ZeDrive
Страница 10: ...Page 9 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Control Cabinet Wiring...
Страница 18: ...Page 17 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Typical Applications Solutions...
Страница 38: ...Page 37 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Trouble shooting Fault Information...
Страница 45: ...Page 44 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS Complete Code List...
Страница 59: ...Page 58 TO GET ASSISTANCE CALL 919 774 7667 ZENITH PUMPS System Drawings...