Page - 36/54
AFDZP0BA – VCM Zapi 2uC - User Manual
15) NEV3 OUTPUT
% value. Percentage of the battery voltage applied on the EV3 (Laser).
16) NEV2 OUTPUT
% value. Percentage of the battery voltage applied on the EV2 (Back up
alarm).
17) NEV1 OUTPUT
% value. Percentage of the battery voltage applied on the EV1 (battery
unlock).
18) ENCODER #1
Number of pulsed read by the encoder 1.
19) ENCODER #2
Number of pulsed read by the encoder 2.
20) DIGITAL INPUT
It is a decimal value that represent the status of all the digital inputs.
21) DIGITAL INPUT #1
ON/OFF. This is the level of the digital input A8 .
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
22) DIGITAL INPUT #2
ON/OFF. This is the level of the digital input A9 .
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
23) DIGITAL INPUT #3
ON/OFF. This is the level of the digital input A10 .
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
24) DIGITAL INPUT #4
ON/OFF. This is the level of the digital input A18.
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
25) DIGITAL INPUT #5
ON/OFF. This is the level of the digital input A19 .
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
26) DIGITAL INPUT #6
ON/OFF. This is the level of the digital input A20 .
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.
27) DIGITAL INPUT #7
ON/OFF. This is the level of the digital input A21.
ON +VB = When it is closed to positive voltage the input is active.
OFF GND = When it is open the input is not active.