AFDZP0BA – VCM Zapi 2uC - User Manual
Page - 23/54
7.2 CNB Ampseal 23 poles (only for VCM PREMIUM)
B1
AI3
Analog input 3.
B2
AI4
Analog input 4.
B3
AI5
Analog input 5.
B4
AI6
Analog input 6. Read by both microcontrollers.
B5
AI7
Analog input 7. Read by both microcontrollers.
B6
AI8
Analog input 8.
B7
POWER IN 2
Power input 2. The power supply for loads must be
connected here with a fuse in series.
B8
PEV2
Common positive supply for EVP9. Optionally, in the
36-48V version, it is possible to install a Smart driver
on this output.
B9
CHA 2
Phase A of incremental encoder 2. Read by both
microcontrollers.
B10
CHB 2
Phase B of incremental encoder 2. Read by both
microcontrollers.
B11
AI9
Analog input 9.
B12
AI10
Analog input 10.
B13
DI8
Input of the switch DI8. The input is active high.
B14
DI9
Input of the switch DI9. The input is active high.
B15
NEV3
Output of the PWM voltage controlled electrovalve EV3
driver; 2 A maximum continuous current (driving to –
Batt).
B16
PPOT3
Low power regulated output (+5V). Maximum current
75mA.
B17
CHA 1
Phase A of incremental encoder 1. Read by both
microcontrollers.
B18
CHB 1
Phase B of incremental encoder 1. Read by both
microcontrollers.
B19
NPOT
This is a ground reference to be used for encoders
B20
-BATT
Ground. Connect to ground reference.
B21
DI10
Input of the switch DI10. The input is active high. .
B22
DI11
Input of the switch DI11. The input is active high.
B23
NEVP9
Output of the current controlled electrovalve EVP9
driver; 4A maximum continuous current (driving to –
Batt); built-in freewheeling diode to B7.