12 PERIODIC MAINTENANCE TO BE
REPEATED AT TIMES INDICATED
Check the all microswitches. Using a suitable test meter, confirm that there is no
electrical resistance between the contacts by measuring the volt drop between
the terminals. Switches should operate with a firm click sound. Microswitches
should be checked every: ..................................................................... 3 MONTHS
Check the cables to the controller. Ensure the insulation is sound and the
connections are tight. Cables should be checked every: ...................... 3 MONTHS
Check the correct operation of the steering command devices: stepper motor
and/or twin potentiometer. Check every: .............................................. 3 MONTHS
Checks should be carried out by qualified personnel and any replacement parts
used should be original. Beware of NON ORIGINAL PARTS.
The installation of this electronic controller should be made according to the
diagrams included in this Manual. Any variations or special requirements should
be made after consulting a Zapi Agent. The supplier is not responsible for any
problem that arises from wiring methods that differ from information included in
this Manual.
During periodic checks, if a technician finds any situation that could cause
damage or compromise safety, the matter should be bought to the attention of a
Zapi Agent immediately. The Agent will then take the decision regarding
operational safety of the machine.
Remember that Battery Powered Machines feel no pain.
NEVER USE A VEHICLE WITH A FAULTY ELECTRONIC CONTROLLER.
U
IMPORTANT NOTE ABOUT WASTE MANAGEMENT:
This controller has both mechanical parts and high-density electronic parts
(printed circuit boards and integrated circuits). If not properly handled
during waste processing, this material may become a relevant source of
pollution. The disposal and recycling of this controller has to follow the
local laws for these types of waste materials.
Zapi commits itself to update its technology in order to reduce the
presence of polluting substances in its product.