9 PROGRAMMING & ADJUSTMENTS
4
To access and adjust all parameters it is necessary to use the Zapi PC CAN
console. Since the VCM has no external serial connector, the Zapi handset
console can be used only if it is connected in remote through a different module,
like Traction controller, Pump controller or other. This module has to be
connected to the same CAN Bus line of the VCM.
9.1 Description of programmable functions
Here it is shown a list of all programmable functions of the VCM. The list refers to
VCM Premium.
For Standard version it is possible to refer to this list but considering that some
functions or parameters are not available.
4
Each menu and submenu can be different from what shown below according to
the software customization of VCM.
Menu “Set Model”
1) CONNECTED
TO
This parameter is used in systems where multiple modules are connected
through CANbus: when the parameter value is set to a number
corresponding to a node of the CAN line, the console connects to that node
as if it was directly connected. In this way the console operates as a remote
console. The node number corresponding to the VMC is “1”.
2) MODEL
TYPE
This parameter defines if the console must connect to the master
microcontroller or to the supervisor microcontroller. Set the parameter to “0”
to connect the master and to “1” to connect to the slave.
It is possible to choose only if both the uC, master and supervisor, are
connected to the same line (see paragraph 4.5).
Menu “Set Options”
1) HOUR
COUNTER
-
RUNNING: the counter registers travel time only.
-
KEY ON: the counter registers when the "key" switch is closed.
2) EVP1
PRESENT/ABSENT
It enables the EVP1.
3) EVP2
PRESENT/ABSENT
It enables the EVP2.