AFDZP0BA – VCM Zapi 2uC - User Manual
Page - 31/54
It permits to set the hour of the Real Time Clock.
13) WATCH MINUTES
It permits to set the minutes of the Real Time Clock.
Menu “Parameter Change”
1) I MIN EVP1
0 to 100. This parameter determines the minimum current applied on the
EVP1 when the position of the command is at the minimum.
2) I MIN EVP1 OFF
0 to 100. This parameter determines the minimum current applied on the
EVP1 when it is turning off and the position of the command is at the
minimum.
3) I MIDDLE EVP1
0 to 100. This parameter determines the minimum current applied on the
EVP1 when the position of the command is in the middle.
4) I MAX EVP1
From 0 to 100. This parameter determines the maximum current applied to
the EVP1 when the position of the command is at the maximum.
5) I MIN EVP2
0 to 100. This parameter determines the minimum current applied on the
EVP2 when the position of the command is at the minimum.
6) I MAX EVP2
From 0 to 100. This parameter determines the maximum current applied to
the EVP2 when the position of the command is at the maximum.
7) I MIN EVP3
0 to 100. This parameter determines the minimum current applied on the
EVP3 when the position of the command is at the minimum.
8) I MAX EVP3
From 0 to 100. This parameter determines the maximum current applied to
the EVP3 when the position of the command is at the maximum.
9) I MIN EVP4
0 to 100. This parameter determines the minimum current applied on the
EVP4 when the position of the command is at the minimum.
10) I MAX EVP4
From 0 to 100. This parameter determines the maximum current applied to
the EVP4 when the position of the command is at the maximum.
11) I MIN EVP5
0 to 100. This parameter determines the minimum current applied on the
EVP5 when the position of the command is at the minimum.
12) I MAX EVP5
From 0 to 100. This parameter determines the maximum current applied to
the EVP5 when the position of the command is at the maximum.