MODE CONFIGURATION AFTER POWER SUPPLY SWITCH ON
In case of SRP-22 receiver, it is possible to configure its input operation mode after power supply
has been switched on. As a default setting, the roller blind does not change its position.
Possible modes after power supply is switched on:
• open a roller blind / close a roller blind / do not
change roller blind position,
• percentage value – after power supply is switched
on, a roller blind is in a position consistent with a
defined percentage value, understood as a roller
blind closure position.
CAUTION! If there is power supply failure dur-
ing a roller blind movement, then after power
supply is switched on again press the button to
move the roller blind to the top or to the bottom.
IN1, IN2 INPUT FUNCTIONALITY
IN1 and IN2 inputs are used in a wired control of the SRP-22 receiver. They are fully configured by
means of the exta life mobile application. The configuration means choosing this type of roller blind
push-button that is connected to a controller’s input, operation mode of these inputs and roller blind
movement after release from the particular input (it refers only to a double roller blind push-button).
Default settings:
• Switch type: double roller blind push-button.
• Operation mode: local control.
• IN1 input functionality: roller blind closing.
• IN2 input functionality: roller blind opening.
IN1, IN2 inputs are triggered only from the “L” line. The basic functionality requires giving short (< 0,5
sec.) impulses to these inputs. If the inputs operate in the local mode, then giving a longer phase (>
2 sec.) to an input causes one of the favourite settings is activated (roller blind position). In case of a
single push-button, only one favourite setting is activated (programmed as “Favourite_1”). If inputs
are configured to operate with single push-buttons by means of a mobile application, then the push-
button can be connected to the IN1 or IN2 input (their operation is the same).
Input configuration change:
1. Activate the application and enter the Device
screen.
2. Select the ‘Configure’ option from the menu of
SRP-22 receiver.
3. Expand the screen and:
• define the push-button type connected to
the IN1 or IN2 input in the ‘Input type’ field.
Choose from ‘double roller blind push-button’
or ‘single roller blind push-button’,
• define the IN1, IN2 input operation mode in
the ‘Input mode’ field. Choose from ‘Local
mode’ or ‘Central mode’.
• if a double roller blind push-button is selected as the input type, then in the next step choose
which button should realise the closing function and which button should realise the opening
function.
4. Press the ‘Save’ button to save all settings – the settings are saved in the receiver.
single push-button
double push-button
local
central
IN1
IN2