OPERATION MODES
FUNCTIONALITY BY CONTROL OF EXTA LIFE SYSTEM
TRANSMITTERS
CAUTION: Two push-buttons of a transmitter are always used in case of SRP-22 roller
blind controller. For example, P-457/4 remote control (4 push-button) allows for independ-
ent control of two SRP-22 receivers (two roller blinds).
Particular push-buttons of radio EXTA LIFE transmitters can be assigned to different operation
modes: local and central (see Programming push-buttons of EXTA LIFE radio transmitters).
Local control mode
• Local control mode allows to stop a roller blind in any position. It is used to control one roller
blind. In this mode, pressing shortly one push-button realises the opening function and press-
ing shortly the other push-button realises the closing function. In case a roller blind is in motion,
pressing any push-button causes the roller blinds stops.
• Roller blind movement time upwards / downwards is in accordance with time adjusted in the
controller. The default times are 120 seconds. Longer pressing (>2 sec.) the push-button of a
transmitter causes the activation of favourite settings. By favourite settings we understand a
defined % of roller blind closure. In case of local control, it is possible to programme only two
favourite settings, which are activated independently on current roller blind position.
Central control mode
Central control mode allows only for a total opening or closure of a single roller blind or a group of
roller blinds. In this mode, it is not possible to stop a roller blind in a desired position. The central
mode is used mainly to control a group of roller blinds or to cooperate with sensors. In this mode,
pressing shortly one push-button realises the opening function and pressing shortly the other
push-button realises the closing function. In case a roller blind is opened, pressing the closing
push-button causes the roller blind stops (for about 0,5 sec.) and automatically closes it. The
same occurs in case of closing a roller blind. Its movement time either upward or downward is in
accordance with time adjusted in the controller. The default times are 120 seconds.
FUNCTIONALITY BY CONTROL OF IN1, IN2 EXTERNAL INPUTS
DOUBLE ROLLER BLIND PUSH-BUTTON
Local control
In this mode, pressing shortly (<0,5 sec.) suitable push-buttons connected to IN1, IN2 inputs,
activates the following modes: opening, closing or stopping a roller blind. Roller blind movement
time is in accordance with time adjusted in the controller (default time is 120 sec.). Pressing the
local control push-button for the first time, causes the roller blind moves in a selected direction,
however the subsequent push-button pressing stops the roller blind. Longer pressing (>2 sec.) the
suitable local control push-button causes the activation of favourite settings. By favourite settings
we understand a defined % of roller blind closure. The settings are activated independently of
current roller blind position.
CAUTION: Favourite settings are common for external outputs and push-buttons of ra-
dio transmitters. If the SRP-22 controller is paired with the EXTA LIFE controller, then
by means of a mobile application, it is possible to define the roller blind motion by IN1
and IN2 input.