Central control

In this mode, pressing shortly (<0,5 sec.) suitable push-buttons connected to IN1, IN2 inputs, ac-

tivates the following modes: opening and closing a roller blind. After the adjusted time is over, the 

roller blind is stopped. Its default time is 120 sec. In case the roller blind is in motion, but there is 

a central order (impulse) contrary to its moving direction, then the roller blind is stopped for about 

0,5 sec. and it automatically moves in the opposite direction.

CAUTION:  IN1,  IN2  input  configuration  to  operate  in  the  central  mode  is  possible  only 

by means of the EXTA LIFE mobile application, but in cooperation with a controller. This 

application defines the function of IN1 and IN2 input (upward / downward movement of a 

roller blind).

SINGLE ROLLER BLIND PUSH-BUTTON

Local control

In this mode, pressing shortly (<0,5 sec.) a roller blind push-button activates the following modes: 

opening, closing or stopping. Roller blind movement time is in accordance with time adjusted in 

the controller. The default time is 120 seconds. The roller blind movement operates according to 

a sequence: open – stop - close. Longer pressing (>2 sec.) a push-button causes the activation 

of programmed favourite settings. By favourite settings we understand a defined % of roller blind 

closure.  A single push-button can activate only one favourite setting (programmed as setting “1”). 

Central control

In this mode, pressing shortly (<0,5 sec.) a roller blind push-button, the SRP-22 activates only 

the following modes: opening and closing. Roller blind movement time is in accordance with time 

adjusted in the controller. The default time is 120 seconds. The roller blind movement operates 

according to a sequence: open – stop for about 0,5 sec. – close.

CAUTION: To connect a single roller blind push-button, configure inputs by means of a 

mobile application in cooperation with the EXTA LIFE controller. Select the type of input 

‘single roller blind push-button’ and define the input operation mode as ‘Local mode’ or 

‘Central mode’. If the input type understood as “Single roller blind push-button” is se-

lected by means of the mobile application, the push-button can be connected to IN1 or 

IN2 input (their operation is the same). The single push-button can also be connected by 

a short-circuit of IN1 and IN2 inputs (configuration by means of a mobile application is 

not required then).

FUNCTIONALITY BY MEANS OF EXTA LIFE

MOBILE APPLICATION CONTROL

Control of the SRP-22 receiver by means of a mobile application is possible only after it has been 

paired with the EXTA LIFE controller (see SRP-22 RECEIVER REGISTER (PAIRING) in EXTA 

LIFE SYSTEM).

After pairing, the controller is visible on the receivers’ list in the EXTA LIFE system and can be 

controlled at once.

Содержание SRP-22

Страница 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Страница 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Страница 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Страница 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Страница 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Страница 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Страница 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Страница 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Страница 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Страница 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Страница 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Страница 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Страница 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Страница 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Страница 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Страница 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...

Отзывы: