background image

FUNCTIONALITY 

1.  SRP-22 roller blind controller can be simultaneously controlled by:

a.  EXTA LIFE system transmitters / IN1, IN2 external inputs

•  local control mode, 

•  central control mode,

•  activation up to two favourite settings,

•  in case of external inputs, control by means of single and double push-buttons,

b.  the EXTA LIFE mobile application after pairing with a controller,

•  close / open / stop type of control by means of control push-buttons,

•  % adjustment of roller blind closing position by means of a slide,

•  activation of 4 favourite settings maximum.

2.  Current roller blind position is shown in the mobile application (% of c icon). The icon 

indicates only 3 modes: fully opened roller blind, fully closed roller blind, half opened roller blind.

3.  It is possible to assign a larger number of push-buttons of EXTA LIFE radio transmitters to one 

controller – maximum 96 pairs (e.g. 24 transmitters in a local mode).  

4.  Transmitters’ push-buttons can be assigned to the SRP-22 controller by means of the PROG. 

push-button, or „remotely” by means of the mobile application (without a direct access to a dim-

mer).

5.  Few SRP-22 controllers can cooperate with one transmitter – it enables to group roller blinds 

(central mode is recommended in this situation) or to control a roller blind independently from 

different places.

6.  A roller blind controller can be paired only with one EXTA LIFE controller (after pairing, it is not 

visible for other controllers).

7.  Push-buttons added to SRP-22 can be selectively deleted. 

8.  There is a possibility to delete simultaneously all push-buttons added to a controller’s memory 

(reset to default settings).

9.  Basic SRP-22 parameters are configured by means of the mobile application. 

10. A remote software update of a controller is also possible due to the mobile application (the EXTA 

LIFE controller must be connected to the Internet).

3. It is recommended that the position of a roller blind connected to a controller during instal-

lation and programming is in its minimum or maximum position (completely open or closed). 

Otherwise, just after programming the remote control or pairing the drive with the controller, 

it is necessary to force the movement of a roller blind to adjust its position to the minimum or 

maximum (up or down). 

4. It is possible to connect debouncing roller blind push-buttons to IN1 and IN2 inputs in a wired 

way of control. By default, the controller cooperates with double debouncing roller blind push-

buttons. To connect a single push-button, it is necessary to short-circuit IN1 and IN2 inputs or to 

adjust “Single roller blind push-button” by means of a mobile application as an input type (then 

it is possible to connect the push-button to the IN1 or IN2 input).

5. During mounting, make sure the receiver is not exposed to direct water and operation in an 

increased humidity environment. The mounting ambient temperature range should be within 

the range from -10 to + 55 °C.

6. The SRP-22 controller is designed to be mounted indoor. In case the controller is mounted 

outdoor, it must be placed in an additional hermetic casing.

7. After the SRP-22 receiver has been installed, it is important to check if it operates correctly. In 

case of control by means of the EXTA LIFE system transmitters, they must be first programmed 

with a receiver (see Programming transmitters). In case of cooperation with a controller, a 

correct pairing of a receiver with a controller is required (see Register of receivers in the EXTA 

LIFE system). Local inputs in the default setting mode are ready to operate at once.

Содержание SRP-22

Страница 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Страница 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Страница 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Страница 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Страница 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Страница 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Страница 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Страница 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Страница 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Страница 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Страница 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Страница 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Страница 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Страница 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Страница 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Страница 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...

Отзывы: