REGISTRATION (PAIRING) SRP-22 IN THE EXTA LIFE SYSTEM

In order to register SRP-22 in the system, it is necessary to connect the EXTA LIFE controller in the 

system and to install the EXTA LIFE mobile application. The receivers must be connected to 230 V 

AC. They are remembered in the system only after they have been properly paired with a controller. 

To do it carry out the following steps:

1.  Activate the application and enter the Device 

screen.

2.  Choose the receiver tab and press „+” 

 to 

start the searching process of receivers in-

stalled in the system. It lasts no longer than 

60 seconds and can be stopped by means of 

the „Stop” push-button. All receivers located 

within the controller are automatically dis-

played in a list form with a default icon and 

a default name including the receiver’s name 

(SRP-22) + 6-digit ID serial number 

 as-

signed to this receiver.

3. After searching has been completed 

press the ‘TEST’ push-button to quickly lo-

cate the receiver (press the TEST push-but-

ton alternately so that the roller blind moves 

up  or  down).  By  marking  fields  next  to  the 

‘TEST’ push-button 

, we choose receivers 

to be paired with the EXTA LIFE controller. It 

is possible to mark more than one receiver.

4.  Press the ‘PAIR’ push-button to pair the 

marked receivers. After a while the receivers 

are registered in the system and are visible on 

the list in the Receivers tab 

.

5.  After pairing, there is one default icon as-

signed to the SRP-22 receiver.

6.  The receivers, just after pairing, can be con-

trolled at once by means of application but-

tons. The receiver’s mode is signalled by the 

“Closure level” parameter – given in %. By de-

fault, control is carried out in the close – stop – open mode. The roller 

blind movement time is consistent with time configured in the SRP-22 

controller.

7.  The receivers can be paired individually – press the “PAIR” push-

button and assign a new name to a receiver. In case a larger number of 

receivers are paired, they are automatically saved with default names.

8.  After pairing, it is possible to add an individual name and icon (from the 

icon base) to each SRP-22 receiver.

9.  Only after pairing, the receivers can be used in the system in a further 

configuration process (assigning a user, a category, building scenes, 

time and logic functions).

Содержание SRP-22

Страница 1: ...operate in a local or central control mode Single and double roller blind push buttons can be applied in both cases Due to the two way communication between a receiver and a controller the current rol...

Страница 2: ...special measuring equip ment 3 Connect the device cables with the terminals in accordance with the installing diagram 4 Install SRP 22 in a junction box 5 Switch on the power supply from the mains and...

Страница 3: ...means of the mobile application 10 A remote software update of a controller is also possible due to the mobile application the EXTA LIFE controller must be connected to the Internet 3 It is recommende...

Страница 4: ...a roller blind in a desired position The central mode is used mainly to control a group of roller blinds or to cooperate with sensors In this mode pressing shortly one push button realises the opening...

Страница 5: ...blind closure A single push button can activate only one favourite setting programmed as setting 1 Central control In this mode pressing shortly 0 5 sec a roller blind push button the SRP 22 activates...

Страница 6: ...perate properly by means of the mobile application The of roller blind closure is calculated on the basis of these times Favourite position positions By means of a mobile application it is possible to...

Страница 7: ...means of the EXTA LIFE mobile application DIRECT PROGRAMMING BY MEANS OF PROG PUSH BUTTON To assign radio transmitters directly to a receiver use the receiver s PROG push button ASSIGNING PUSH BUTTON...

Страница 8: ...ed 1 Pair the selected SRP 22 receiver with a controller 2 Pair the controller with a transmitter whose buttons you want to assign remotely to a receiver 3 Choose the Assign a receiver option by means...

Страница 9: ...ckly to signal times have been assigned correctly PROGRAMMING ROLLER BLIND MOTION TIME In the SRP 22 controller the default closing and opening time of a roller blind is adjusted to 120 seconds During...

Страница 10: ...m pletely 2 After a complete roller blind opening press again the Configure closing time push button it causes the roller blind closes 3 Immediately after a complete roller blind closure press again t...

Страница 11: ...ly 2 Press the PROG push button shortly 1sec in a receiver STATUS LED switches on blue 3 Wait for about 5 seconds till STATUS LED switches on red 4 Wait another 5 seconds till STATUS LED switches off...

Страница 12: ...utton and in 5 sec press it again shortly 3 The STATUS LED flashes orange to signal the deleting is ongoing The LED flashes orange quickly to signal the operation has been completed successfully FAVOU...

Страница 13: ...E DELETION OF TRANSMITTERS BY MEANS OF EXTA LIFE APLICATION In case we want to delete remotely push buttons of a transmitter from a receiver it is required that the receiver is paired with the EXTA LI...

Страница 14: ...moves up or down By marking fields next to the TEST push button we choose receivers to be paired with the EXTA LIFE controller It is possible to mark more than one receiver 4 Press the PAIR push butto...

Страница 15: ...cess of receivers To protect correctly your system the following steps must be carried out 1 If there is no controller in the EXTA LIFE system switch off pairing Broadcast OFF in all receiv ers 2 If t...

Страница 16: ...ol IN1 input functionality roller blind closing IN2 input functionality roller blind opening IN1 IN2 inputs are triggered only from the L line The basic functionality requires giving short 0 5 sec imp...