background image

' $% ('  

SYS _3 5_ [X]

Caller dials Operator Code X, the call will be transferred to operator number. X=

 regard as null

AD M_ 41 _[ X…]

The 1

st

 operator No. during working hours

AD M_ 42 _[ X…]

The 2

nd

 operator No. during working hours

AD M_ 43 _[ X…]

The 1

st

 Operator No. during break hours

AD M_ 44 _[ X…]

The 2

nd

 Operator No. during break hours

AD M_ 45 _[ X…]

The 1

st

 Operator No. after closing hours

AD M_ 46 _[ X…]

The 2

nd

 Operator No. after closing hours

AD M_ 47 _[ X…]

The 1

st

 Operator No. during holiday

AD M_ 48 _[ X…]

The 2

nd

 Operator No. during holiday

AD M_ 59 94 0_ [X …]

|

AD M_ 59 94 7_ [X …]

The 1

st

 operator No. for Circular Hunting

|       (During working hours)

The 8

th

 operator No. for Circular Hunting

When the Operator No. X… is less than 4 digits, please press # to complete the

digit entering. 0000 means to delete.

EVM will disconnect the call for No-dial after Greeting if SYS_30_[0] or the
operator number is not set or disable. (See page 16)

If there has been set an Area Code (See page 11), then the input of operator
number shall exclude Area Code, except the operator number having only a
single digit.

If the extension number of Personnel on Duty is set via ADM_5[Y]_[X…], and if Y
is the same as Operator Code, then X … is regarded as operator number.

The Circular Hunting is only used on working hours. You may set the operator
number without this function by ADM_41_[X…].

!

Examples for operator number

Working hours

Closing hours

Break hours

Program Setting

No-d ia l

Di al  0

No-d ia l

Di al  0

No-d ia l

Di al  0

To

operator

To

operator

To

operator

To

operator

To

operator

To

operator

"

SYS_30_[2]: Redial operator 2 times   

"

 SYS_35_[0]: Operator code is 0

"

ADM_59940_[100]#, ADM_59941_[101]#, ADM_59942_[102]#: During working

hours, the Operator Numbers are 100, 101 and 102 with Circular Hunting.

"

ADM_43_[300]#: During break hours, the Operator number is 300.

"

ADM_45_[1000]: During closing hours, the Operator number is 1000.

Working hours

Closing hours

Break hours

Program Setting

No-d ia l

Di al  0

No-d ia l

Di al  0

No-d ia l

Di al  0

To

operator

To

operator

Dis-

connect

To

Extn on

Duty

To

operator

To

operator

"

SYS_30_[2]: Redial operator 2 times   

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[100]#: During working hours, the Operator Number is 100

"

ADM_43_[300]#: During break hours, the Operator Number is 300

"

ADM_45_[0000]: No operator during closing hours

"

ADM_5[0]#_[200]#: During closing hours, dial 0 to Extn 200 on Duty

To

operator

To

operator

Dis-

connect

To

Extn on

Duty

Dis-

connect

To

Extn on

Duty

"

SYS_30_[2]: Redial operator 2 times   

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[100]#: During working hours, the Operator Number is 100

"

No operator during break and closing hours

"

ADM_5[0]#_[200]#: During break and closing hours, dial 0 to Extn 200 on Duty

To

operator

To

operator

Dis-

connect

Dis-

connect

Dis-

connect

Dis-

connect

"

SYS_30_[2]: Redial operator 2 times     

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[9]: During working hours, the Operator Number is 9

"

No operator during break and closing hours

Dis-

connect

To

operator

Dis-

connect

To

operator

Dis-

connect

To

operator

"

SYS_30_[0]: Disconnect for No-dial   

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[100]#: During working hours, the Operator Number is 100

"

ADM_43_[300]#: During break hours , the Operator Number is 300

"

ADM_45_[200]#: During closing hours, the Operator Number is 200

Dis-

connect

To

operator

Dis-

connect

Dis-

connect

Dis-

connect

To

operator

"

SYS_30_[0]: Disconnect for No-dial   

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[100]#: During working hours, the Operator Number is 100

"

ADM_43_[300]#: During break hours, the Operator Number is 300

"

No operator during closing hours

Dis-

connect

To

operator

Dis-

connect

Dis-

connect

Dis-

connect

Dis-

connect

"

SYS_30_[0]: Disconnect for No-dial   

"

 SYS_35_[0]: Operator code is 0

"

ADM_41_[100]#: During working hours, the Operator Number is 100.

"

No operator during break and closing hours.

Dis-

connect

Dis-

connect

Dis-

connect

Dis-

connect

Dis-

connect

Dis-

connect

"

SYS_35_[

]: No operator code

"

No operators during working hours, break hours and closing hours.

 

:

Содержание EVM1001

Страница 1: ...0 0 0 1 2 3 4 5 6 0 7 0 7 7 0 0 0 4 8 7 9 0 7...

Страница 2: ...er ID recognized Line busy ID recognized No ID Code recognized Busy tone detected Unanswered Answered Unsupervised Transfer 7 If no recorded message No receptionist No receptionist If no recorded mess...

Страница 3: ...e unit close to frequency generator Power supply radio broadcast in 2 meter distances above any vibrating machines After revising data voice message please enter SYS_199_ or ADM_2199_ to transmit the...

Страница 4: ...he actual case See page 11 Before the EVM build up the range of Extn Group 01 if you dial extension number the Please wait message will be heard after 2 seconds If the response is incorrect please del...

Страница 5: ...urs ADM_12 Switch to break hours ADM_13 Switch to closing hours ADM_14 Switch to holiday ADM_15 Switch to temporary announcement ADM_16 Auto Switch the system will automatically switch the Greeting me...

Страница 6: ...s Built in English in 1st language Greeting for working hours Hello please dial extension numbers or wait for the operator service 5 Greeting for break hours Hello we are on break now please dial exte...

Страница 7: ...lexible length pause for 3 seconds after the Pth digit If P 0 it means EVM will only detect Busy tone cycle for this group p pause for XX seconds SYS_20_ XX after the pth digit If p 0 it means EVM wil...

Страница 8: ...ours Closing hours Break hours Program Setting No dial Dial 0 No dial Dial 0 No dial Dial 0 To operator To operator Dis connect To Extn on Duty To operator To operator SYS_30_ 2 Redial operator 2 time...

Страница 9: ...ering X is not confined to the range of the Extn Groups Example 1 Caller dials 6 to Extn 1234 ADM_5 6 _ 1234 Example 2 Caller dials 201 to Extn 202 ADM_5 201 _ 202 Example 3 Callers dial 7 for Ext 301...

Страница 10: ...er Administrator Program Program Prompt Welcome to Administrator Program Please refer to the operation instruction of PABX extension SYS_52_ X EVM releases after call answered Default 5 SYS_53_ X EVM...

Страница 11: ...SYS_754_ XXX X XX sec is 2nd OFF of Busy tone cycle SYS_761_ XXX X XX sec is 1st ON of Ring back tone cycle SYS_762_ XXX X XX sec is 1st OFF of Ring back tone cycle SYS_763_ XXX X XX sec is 2nd ON of...

Страница 12: ...3 C enter 4 YY Number of digit s ahead Extn of the ID Code YY 99 indicates that PABX will respond ID Code immediately after receiving the extension number It should only apply to busy line identifica...

Страница 13: ...e Menu No as below During working hours if callers dial 1 the route will be from Greeting to Menu 1 During break hours if callers dial 1 the route will be from Greeting to Menu 71 During closing hours...

Страница 14: ...cally configure HOOK FLASH by setting the starting time from at least 0 13 seconds and up to certain ranges depending on PABX If the setting time of your PABX is less than 0 13 seconds Please set SYS_...

Страница 15: ...sic data EVM Programming for Specific PABXs PABX Operating way Function Code Others ALCTEL 4200 SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 SYS_45_ 2 LUCENT PROLOGIX SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 NAKAYO 64IS 88IS S...

Страница 16: ...one SYS_75_ SYS_64_ SYS_55_ 1 No Answer ID Code Retrieving call No Answer Ring Back tone SYS_76_ SYS_63_ SYS_56_ 1 Operator No Hunting Port locked up Auto detection ADM_59940_ SYS_47_ 2 ADM_59941_ Pre...

Страница 17: ......

Отзывы: