background image

$% (&

AD M_ 50 00 0_ 0 00 0

Delete all the setting for number forwarding

AD M_ 5[ Y…]_ [X …]

Caller dials No. Y… will be transferred to Extn X…

AD M_ 5[ Y…]_

00 1

Caller dials No. Y… will be transferred to the Extn of Hunt Group-1

AD M_ 59 95 0_ [X …]

|

AD M_ 59 95 3_ [X …]

X…is the 1

st

 Extn of the Hunt Group-1

|

X…is the 4

th

 Extn of the Hunt Group-1

AD M_ 59 95 4_ [X ]

The hunting mode of Hunt Group-1;    X: 1=Circular    2=Pilot

AD M_ 5[ Y…]_

00 2

Caller dials No. Y… will be transferred to the Extn of Hunt Group-2

AD M_ 59 95 5_ [X …]

|

AD M_ 59 95 8_ [X …]

X…is the 1

st

 Extn of the Hunt Group-2

|

X…is the 4

th

 Extn of the Hunt Group-2

AD M_ 59 95 9_ [X ]

The hunting mode of Hunt Group-2;    X: 1=Circular    2=Pilot

AD M_ 5[ Y…]_

00 3

Caller dials No. Y… will be transferred to the Extn of Hunt Group-3

AD M_ 59 96 0_ [X …]

|

AD M_ 59 96 3_ [X …]

X…is the 1

st

 Extn of the Hunt Group-3

|

X…is the 4

th

 Extn of the Hunt Group-3

AD M_ 59 96 4_ [X ]

The hunting mode of Hunt Group-3;    X: 1=Circular    2=Pilot

AD M_ 5[ Y…]_

00 4

Caller dials No. Y… will be transferred to the Extn of Hunt Group-4

AD M_ 59 96 5_ [X …]

|

AD M_ 59 96 8_ [X …]

X…is the 1

st

 Extn of the Hunt Group-4

|

X…is the 4

th

 Extn of the Hunt Group-4

AD M_ 59 96 9_ [X ]

The hunting mode of Hunt Group-4;    X: 1=Circular    2=Pilot

Y…=0~9899, if Y… is less than 4 digits please press
# sign to complete the digit entering

X…=1~8999, if X… is less than 4 digits please press
# sign to complete the digit entering

X… is not confined to the range of the Extn Groups.

Example 1. Caller dials 6 to Extn 1234:

"

ADM_5[6]

_[1234]

Example 2. Caller dials 201 to Extn 202:

"

ADM_5[201]

_[202]

Example 3. Callers dial 7 for Ext. 301~304 (with Circular

Hunting) programming as follows:

"

ADM_5[7]

_

001

"

ADM_59950_[301]

"

ADM_59951_[302]

"

ADM_59952_[303]

"

ADM_59953_[304]

"

ADM_59954_[1]

AD M_ 5[ Y…]_

00 5

Caller dials No. Y… will be transferred to the Extn of Hunt Group-4

AD M_ 59 97 0_ [X …]

|

AD M_ 59 97 3_ [X …]

X…is the 1

st

 Extn of the Hunt Group-5

|

X…is the 4

th

 Extn of the Hunt Group-5

AD M_ 59 97 4_ [X ]

The hunting mode of Hunt Group-5;    X: 1=Circular    2=Pilot

AD M_ 5[ Y…]_

00 6

Caller dials No. Y… will be transferred to the Extn of Hunt Group-4

AD M_ 59 97 5_ [X …]

|

AD M_ 59 97 8_ [X …]

X…is the 1

st

 Extn of the Hunt Group-6

|

X…is the 4

th

 Extn of the Hunt Group-6

AD M_ 59 97 9_ [X ]

The hunting mode of Hunt Group-6;    X: 1=Circular    2=Pilot

  

SYS _3 6_ [X]

Callers dial X, EVM plays Greeting of 2

nd

 language.

SYS _3 7_ [X]

Callers dial X, EVM plays Greeting of 3

rd

 language.

SYS _3 8_ [X]

Callers dial X, EVM plays Greeting of 4

th

 language.

Regard as null if X=

.

$! 

SYS _3 0_ [X]

EVM will transfer the calls to operator for X times (Default =1) if the caller does not dial any number after EVM announces Greeting
or Operator Busy prompt.
If X=0 or operator number is not set, EVM will disconnect the call for No-dial after Greeting.

SYS _4 4_ [X]

Route options for No-dial after Busy/ No-answer prompt.
X: 1= Call transfer to operator or backup Ext.(Default), 2= Disconnect the call after Busy/ No-answer prompt is repeated once again.

.

Содержание EVM1001

Страница 1: ...0 0 0 1 2 3 4 5 6 0 7 0 7 7 0 0 0 4 8 7 9 0 7...

Страница 2: ...er ID recognized Line busy ID recognized No ID Code recognized Busy tone detected Unanswered Answered Unsupervised Transfer 7 If no recorded message No receptionist No receptionist If no recorded mess...

Страница 3: ...e unit close to frequency generator Power supply radio broadcast in 2 meter distances above any vibrating machines After revising data voice message please enter SYS_199_ or ADM_2199_ to transmit the...

Страница 4: ...he actual case See page 11 Before the EVM build up the range of Extn Group 01 if you dial extension number the Please wait message will be heard after 2 seconds If the response is incorrect please del...

Страница 5: ...urs ADM_12 Switch to break hours ADM_13 Switch to closing hours ADM_14 Switch to holiday ADM_15 Switch to temporary announcement ADM_16 Auto Switch the system will automatically switch the Greeting me...

Страница 6: ...s Built in English in 1st language Greeting for working hours Hello please dial extension numbers or wait for the operator service 5 Greeting for break hours Hello we are on break now please dial exte...

Страница 7: ...lexible length pause for 3 seconds after the Pth digit If P 0 it means EVM will only detect Busy tone cycle for this group p pause for XX seconds SYS_20_ XX after the pth digit If p 0 it means EVM wil...

Страница 8: ...ours Closing hours Break hours Program Setting No dial Dial 0 No dial Dial 0 No dial Dial 0 To operator To operator Dis connect To Extn on Duty To operator To operator SYS_30_ 2 Redial operator 2 time...

Страница 9: ...ering X is not confined to the range of the Extn Groups Example 1 Caller dials 6 to Extn 1234 ADM_5 6 _ 1234 Example 2 Caller dials 201 to Extn 202 ADM_5 201 _ 202 Example 3 Callers dial 7 for Ext 301...

Страница 10: ...er Administrator Program Program Prompt Welcome to Administrator Program Please refer to the operation instruction of PABX extension SYS_52_ X EVM releases after call answered Default 5 SYS_53_ X EVM...

Страница 11: ...SYS_754_ XXX X XX sec is 2nd OFF of Busy tone cycle SYS_761_ XXX X XX sec is 1st ON of Ring back tone cycle SYS_762_ XXX X XX sec is 1st OFF of Ring back tone cycle SYS_763_ XXX X XX sec is 2nd ON of...

Страница 12: ...3 C enter 4 YY Number of digit s ahead Extn of the ID Code YY 99 indicates that PABX will respond ID Code immediately after receiving the extension number It should only apply to busy line identifica...

Страница 13: ...e Menu No as below During working hours if callers dial 1 the route will be from Greeting to Menu 1 During break hours if callers dial 1 the route will be from Greeting to Menu 71 During closing hours...

Страница 14: ...cally configure HOOK FLASH by setting the starting time from at least 0 13 seconds and up to certain ranges depending on PABX If the setting time of your PABX is less than 0 13 seconds Please set SYS_...

Страница 15: ...sic data EVM Programming for Specific PABXs PABX Operating way Function Code Others ALCTEL 4200 SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 SYS_45_ 2 LUCENT PROLOGIX SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 NAKAYO 64IS 88IS S...

Страница 16: ...one SYS_75_ SYS_64_ SYS_55_ 1 No Answer ID Code Retrieving call No Answer Ring Back tone SYS_76_ SYS_63_ SYS_56_ 1 Operator No Hunting Port locked up Auto detection ADM_59940_ SYS_47_ 2 ADM_59941_ Pre...

Страница 17: ......

Отзывы: