SYS_45_[X]
X: 1= Dial tone detection after HOOK-FLASH (Default) 2= No If no Dial tone appears after HOOK-FLASH, please set X=2
SYS_46_[X]
X: 1= Large deviation in tone cycle detection If the Busy/ Ring back tone cycle of PABX is irregular 2= Normal (Default)
SYS_48_[X]
X: 1= Detect frequency of CPT (Default) 2= No If the CPT frequency is not within 300~640Hz please set X=2
SYS_51_[X]
X: 1= DTMF 2= Long DTMF 3= Pulse It is the Dialing Mode for transferring code from EVM to PABX.
SYS_71_[XXX]
HOOK-FLASH time is X.XX sec.
EVM is able to auto configure the HOOK-FLASH time (see page 7). If HOOK-FLASH time of PABX
is less than 0.13 seconds or there is no dial tone after HOOK-FLASH, please input this data by yourself.
SYS_72_[XXX]
X.XX seconds is length of each ringing signal of internal rings (Default = none, 000 means to delete). This is for EVM to detect
callback rings when unanswered.
SYS_73_[XXX]
Pause before tone cycle detection is X.XX sec. (Default =0.03 sec.)
SYS_741_[XXX]
X.XX sec. is 1
st
ON of Error tone cycle
SYS_742_[XXX]
X.XX sec. is 1
st
OFF Error tone cycle
SYS_743_[XXX]
X.XX sec. is 2
nd
ON Error tone cycle
SYS_744_[XXX]
X.XX sec. Is 2
nd
OFF Error tone cycle
SYS_751_[XXX]
X.XX sec. is 1
st
ON of Busy tone cycle
SYS_752_[XXX]
X.XX sec. is 1
st
OFF of Busy tone cycle
SYS_753_[XXX]
X.XX sec. is 2
nd
ON of Busy tone cycle
SYS_754_[XXX]
X.XX sec. is 2
nd
OFF of Busy tone cycle
SYS_761_[XXX]
X.XX sec. is 1
st
ON of Ring back tone cycle
SYS_762_[XXX]
X.XX sec. is 1
st
OFF of Ring back tone cycle
SYS_763_[XXX]
X.XX sec. is 2
nd
ON of Ring back tone cycle
SYS_764_[XXX]
X.XX sec. is 2
nd
OFF of Ring back tone cycle
•
Error tone data can be empty if all unused extension numbers
were set. (See page11)
•
EVM is able to auto configure the tone cycle parameters. But
you can input the parameter directly by reading data from
SYS_77x_[XXX]
•
If XXX=000, it means to delete
$
SYS _7 71 _[ XXX ]
Tone cycle 1
st
ON is X.XX sec. of the final transferring.
SYS _7 72 _[ XXX ]
Tone cycle 1
st
OFF is X.XX sec. of the final transferring.
SYS _7 73 _[ XXX ]
Tone cycle 2
nd
ON is X.XX sec. of the final transferring.
SYS _7 74 _[ XXX ]
Tone cycle 2
nd
OFF is X.XX sec. of the final transferring.
•
This is the tone cycle report of the final transferring.
•
f the EVM fails to detect Ring back tone/ Busy tone, please
read this report to examine the failed reason.
SYS _7 81 _0 00
To delete Call Progress Tone (CPT) parameters and recovery to Auto-configuration
B: To increase the sensitivity of CPT detection 0=0db(Default) 1=2db 2=4db 3=6db 4=8db 5=10db 6=12db 7=14db
ADM_59908_x[BC]
C: Filter out the OFF time of tone cycle
0=66ms 1=99ms(Default) 2=132ms 3=165ms 4=198ms 5=231ms 6=264ms 7=297ms 8=330ms
Example. The Ring back tone cycle of M brand PABX is as follow, it should filter out 0.15 seconds OFF time of tone cycle. (By
ADM_59908_xx[4]
)
7;
4 times 0.15sec. on/off 1 sec. off 4 times 0.15 sec. on/off