background image

) ($% *!

SYS _2 1_ [XX ]

Waiting time for caller to dial numbers after Greeting/ Busy/ No-answer prompt. (Default=03 sec.)

SYS _2 2_ [XX ]

Waiting time for the operator answering during working hours (Default =20 sec.)

SYS _2 3_ [XX ]

Waiting time for the operator answering during closing hours (Default =20 sec.)

SYS _2 4_ [XX ]

Waiting time for the extension answering during working hours (Default =20 sec.)

SYS _2 5_ [XX ]

Waiting time for the extension answering during closing hours (Default =20 sec.)

XX=00 means Unsupervised Transfer

If Unsupervised Transfer is set, you can set
Function Code of Call Pickup to retrieve the
unanswered call or set ID Code for "No-
answer" prompt.

SYS _2 7_ [XX ]

Waiting time for Call Pickup (Default = 20 seconds).

The waiting time should be short and shorter than the Ringing time set by

PABX to prevent Pickup calls by mistakes.

SYS _3 1_ [X]

Number of rings to wait before the EVM answers incoming calls.

(' *

SYS _4 1_ [X]

X: 1=Number Repeat (Default)    2=No    If X=1, then EVM will announce "extension number" and "please wait" before transferring

SYS _4 3_ [X]

X: 1=Raise the volume of greeting messages    2=No(Default)

SYS _4 7_ [X]

X: 1=Ext. Port auto detection    2=No(Default)      If you know PABX may lockout the EVM Ext. Port , please set X=1

SYS _4 0_ [X]

X: 1= Silent compression(Default)    2= No silent compression

SYS _6 8_ [

XXXX

]

System Program Password (Default = 0

0

)

SYS _6 9_ [

XXXX

]

Administrator Program Password(Default = none); The first 2 digits can not be the same as System Program Password

SYS _8

Report of remained voice message capacity; Program Prompt: "8""Beep""XXXX(seconds)"

SYS _9

Report the version of EVM. Program Prompt: "XXXXXXXX"

SYS _0

Wait for 2 seconds to enter Administrator Program. Program Prompt: “Welcome to Administrator Program”

' )( ** (  +

Please refer to the operation instruction of PABX extension.

SYS_52_[X]

EVM releases after call answered (Default=5)

SYS_53_[X]

EVM releases for Unsupervised Transfer(Default=5)

SYS_54_[X]

Retrieving call when Error Tone(Default=1)

SYS_55_[X]

Retrieving call when Busy Tone(Default=1)

SYS_56_[X]

Retrieving call when No-answer(Default=1)

SYS_59_[X]

For Call Pickup (Default=8)
If Function Code of Call Pickup and Unsupervised Transfer were set,
EVM will retrieve the unanswered call with the operating way
SYS_59_[X] after waiting time for Call Pickup is over.

#

Operating way:

1= HOOK-FLASH
2= HOOK-FLASH + Function Code
3= HOOK-FLASH twice
4=

 

HOOK-FLASH

 and then

 ON

 & OFF

 HOOK

5= ON

 & OFF

 HOOK

6= ON

 & OFF

 HOOK + Function Code

7= ON

 & OFF

 HOOK

 and then

 HOOK-FLASH

8= Function Code + Extn
9= Extn + Function Code
0= Defined by ADM_59930_[X…]

= Defined by ADM_59933_[X…]

SYS_61_[X…]

Function Code of call transferring (Default =none)

SYS_62_[X…]

Function Code of Retrieving calls (Default =none)

ADM_59907_[X…]

Function Code of Call Pickup (Default =none)

ADM_59931_[X…]

The 1

st

 Function Code of ADM_59930_[X…] (Default =none)

ADM_59932_[X…]

The 2

nd

 Function Code of ADM_59930_[X…] (Default =none)

ADM_59934_[X…]

The 1

st

 Function Code of ADM_59933_[X…] (Default =none)

ADM_59935_[X…]

The 2

nd

 Function Code of ADM_59933_[X…] (Default =none)

#

If X… less than 4 digits, please press # sign to
complete the digit entering. 0000 means to delete.

#

For special character: 

- enter 

- enter 

1

- enter 

2

B

 - enter 

3

C

 

- enter 

4

ADM_59930_[X…]

Sequence of operating way (Default =none)

ADM_59933_[X…]

Sequence of operating way (Default =none)

#

If X… less than 4 digits, please press # sign to
complete the digit entering. 0000 means to delete.

#

X…    is the sequence of operating way

0=On & Off Hook    1=HOOK-FLASH    2=Extn
3= 1

st

 Function Code    4=2

nd

 Function Code

 

Содержание EVM1001

Страница 1: ...0 0 0 1 2 3 4 5 6 0 7 0 7 7 0 0 0 4 8 7 9 0 7...

Страница 2: ...er ID recognized Line busy ID recognized No ID Code recognized Busy tone detected Unanswered Answered Unsupervised Transfer 7 If no recorded message No receptionist No receptionist If no recorded mess...

Страница 3: ...e unit close to frequency generator Power supply radio broadcast in 2 meter distances above any vibrating machines After revising data voice message please enter SYS_199_ or ADM_2199_ to transmit the...

Страница 4: ...he actual case See page 11 Before the EVM build up the range of Extn Group 01 if you dial extension number the Please wait message will be heard after 2 seconds If the response is incorrect please del...

Страница 5: ...urs ADM_12 Switch to break hours ADM_13 Switch to closing hours ADM_14 Switch to holiday ADM_15 Switch to temporary announcement ADM_16 Auto Switch the system will automatically switch the Greeting me...

Страница 6: ...s Built in English in 1st language Greeting for working hours Hello please dial extension numbers or wait for the operator service 5 Greeting for break hours Hello we are on break now please dial exte...

Страница 7: ...lexible length pause for 3 seconds after the Pth digit If P 0 it means EVM will only detect Busy tone cycle for this group p pause for XX seconds SYS_20_ XX after the pth digit If p 0 it means EVM wil...

Страница 8: ...ours Closing hours Break hours Program Setting No dial Dial 0 No dial Dial 0 No dial Dial 0 To operator To operator Dis connect To Extn on Duty To operator To operator SYS_30_ 2 Redial operator 2 time...

Страница 9: ...ering X is not confined to the range of the Extn Groups Example 1 Caller dials 6 to Extn 1234 ADM_5 6 _ 1234 Example 2 Caller dials 201 to Extn 202 ADM_5 201 _ 202 Example 3 Callers dial 7 for Ext 301...

Страница 10: ...er Administrator Program Program Prompt Welcome to Administrator Program Please refer to the operation instruction of PABX extension SYS_52_ X EVM releases after call answered Default 5 SYS_53_ X EVM...

Страница 11: ...SYS_754_ XXX X XX sec is 2nd OFF of Busy tone cycle SYS_761_ XXX X XX sec is 1st ON of Ring back tone cycle SYS_762_ XXX X XX sec is 1st OFF of Ring back tone cycle SYS_763_ XXX X XX sec is 2nd ON of...

Страница 12: ...3 C enter 4 YY Number of digit s ahead Extn of the ID Code YY 99 indicates that PABX will respond ID Code immediately after receiving the extension number It should only apply to busy line identifica...

Страница 13: ...e Menu No as below During working hours if callers dial 1 the route will be from Greeting to Menu 1 During break hours if callers dial 1 the route will be from Greeting to Menu 71 During closing hours...

Страница 14: ...cally configure HOOK FLASH by setting the starting time from at least 0 13 seconds and up to certain ranges depending on PABX If the setting time of your PABX is less than 0 13 seconds Please set SYS_...

Страница 15: ...sic data EVM Programming for Specific PABXs PABX Operating way Function Code Others ALCTEL 4200 SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 SYS_45_ 2 LUCENT PROLOGIX SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 NAKAYO 64IS 88IS S...

Страница 16: ...one SYS_75_ SYS_64_ SYS_55_ 1 No Answer ID Code Retrieving call No Answer Ring Back tone SYS_76_ SYS_63_ SYS_56_ 1 Operator No Hunting Port locked up Auto detection ADM_59940_ SYS_47_ 2 ADM_59941_ Pre...

Страница 17: ......

Отзывы: