background image

On-site:

 Connect a standard Touch Tone phone set to the “PROG” jack at the rear board of the

 

EVM, pick up the handset and you’ll hear “Welcome to the system

program". Follow the procedures below and Input data.

Remote:

 Dial to EVM from CO line or PABX Ext. line, enter System Password by pressing 

0

0

  during the Greeting message and then you will hear

“Welcome to the system program". Follow the procedures below and Input data.

You can enter Administrator Program by pressing 0 during the System Program prompt.

You can enter Administrator Program by pressing 

  plus Administrator Password during the Greeting message.

 

S Y S _ [   ] _ [   ]

DATA

Program Prompt: "ITEM" "Beep" "DATA"

ITEM

Program Prompt: "welcome to the system program"

SYS means System Program
ADM means Administrator Program

[Y…] or [X…] indicates the Item/Data is 1 to 4 digits, if

Item/Data less then 4 digits, press

to complete the digit

entering. eg. X

, XX

, XXX

.

Extn: Extension number

Input new DATA

Press #

  to confirm the

entered data

Press # to leave and go back to Greeting

Wait for 3 seconds

without entering

new data

Program Prompt: "Welcome to the system/administrator program"

Program Prompt:
"ITEM" "Beep" "DATA" "To confirm, press # sign, or re-enter"

Input ITEM

 

SYS_4

_[X]

X: 1=With external switch (See page 3)    2=No external switch (Default)

ADM_11

Switch to working hours

ADM_12

Switch to break hours

ADM_13

Switch to closing hours

ADM_14

Switch to holiday

ADM_15

Switch to temporary announcement

ADM_16

Auto Switch -- the system will automatically switch the Greeting message
based on pre-scheduled business hours.

No more Auto-switch again once set to
operation of 11-15. For example, Jan. 1 to Jan.
4 are the holidays, you may enter 14 (Holiday
announcement) on Dec. 31 after work, and
then enter 16 (Auto-switch) on Jan. 5 when
you come back to work, or you may use
ADM_7 to preset the holidays.

 

ADM_31_[HHMMhhmm]

Mon. working hours from HH(hrs) MM(min.) to hh(hrs) mm(min).

ADM_32_[HHMMhhmm]

Tue. working hours …

ADM_33_[HHMMhhmm]

Wed. working hours …

ADM_34_[HHMMhhmm]

Thus. working hours …

ADM_35_[HHMMhhmm]

Fri. working hours …

ADM_36_[HHMMhhmm]

Sat. working hours …

ADM_37_[HHMMhhmm]

Sun. working hours …

The default time is 0830~1730 for Mon. to Fri.

1200~1300 for break hour (in a 24 hour
format)

Eight zeros mean holiday.

ADM_38_[HHMMhhmm]

Break hours …                                         (Default = 1200~1300)  0000 0000 means to delete.

ADM_39_[YYYYMODD]

Set present date to YYYY(year) MO(month) DD(day).

ADM_30_[HHMMSSW]

Set present time to HH(hrs) MM(min.) SS(sec.), W(week).    W: 7 for Sunday, 1 for Monday, and so-forth.

ADM_3

_[X]

The system clock will auto-adjust at every midnight.    X: 1 for 1 sec. faster,    2 for 1 sec. slower.
Program Prompt: "4" means auto-adjust slower 4 seconds every day,"4A" means auto-adjust faster 4 seconds every day.

ADM_7[YY]_[MODD]

To preset holidays within the year. Index No YY= 01~64; Date: MO(month) DD(day). 0000 means to delete.

 

Содержание EVM1001

Страница 1: ...0 0 0 1 2 3 4 5 6 0 7 0 7 7 0 0 0 4 8 7 9 0 7...

Страница 2: ...er ID recognized Line busy ID recognized No ID Code recognized Busy tone detected Unanswered Answered Unsupervised Transfer 7 If no recorded message No receptionist No receptionist If no recorded mess...

Страница 3: ...e unit close to frequency generator Power supply radio broadcast in 2 meter distances above any vibrating machines After revising data voice message please enter SYS_199_ or ADM_2199_ to transmit the...

Страница 4: ...he actual case See page 11 Before the EVM build up the range of Extn Group 01 if you dial extension number the Please wait message will be heard after 2 seconds If the response is incorrect please del...

Страница 5: ...urs ADM_12 Switch to break hours ADM_13 Switch to closing hours ADM_14 Switch to holiday ADM_15 Switch to temporary announcement ADM_16 Auto Switch the system will automatically switch the Greeting me...

Страница 6: ...s Built in English in 1st language Greeting for working hours Hello please dial extension numbers or wait for the operator service 5 Greeting for break hours Hello we are on break now please dial exte...

Страница 7: ...lexible length pause for 3 seconds after the Pth digit If P 0 it means EVM will only detect Busy tone cycle for this group p pause for XX seconds SYS_20_ XX after the pth digit If p 0 it means EVM wil...

Страница 8: ...ours Closing hours Break hours Program Setting No dial Dial 0 No dial Dial 0 No dial Dial 0 To operator To operator Dis connect To Extn on Duty To operator To operator SYS_30_ 2 Redial operator 2 time...

Страница 9: ...ering X is not confined to the range of the Extn Groups Example 1 Caller dials 6 to Extn 1234 ADM_5 6 _ 1234 Example 2 Caller dials 201 to Extn 202 ADM_5 201 _ 202 Example 3 Callers dial 7 for Ext 301...

Страница 10: ...er Administrator Program Program Prompt Welcome to Administrator Program Please refer to the operation instruction of PABX extension SYS_52_ X EVM releases after call answered Default 5 SYS_53_ X EVM...

Страница 11: ...SYS_754_ XXX X XX sec is 2nd OFF of Busy tone cycle SYS_761_ XXX X XX sec is 1st ON of Ring back tone cycle SYS_762_ XXX X XX sec is 1st OFF of Ring back tone cycle SYS_763_ XXX X XX sec is 2nd ON of...

Страница 12: ...3 C enter 4 YY Number of digit s ahead Extn of the ID Code YY 99 indicates that PABX will respond ID Code immediately after receiving the extension number It should only apply to busy line identifica...

Страница 13: ...e Menu No as below During working hours if callers dial 1 the route will be from Greeting to Menu 1 During break hours if callers dial 1 the route will be from Greeting to Menu 71 During closing hours...

Страница 14: ...cally configure HOOK FLASH by setting the starting time from at least 0 13 seconds and up to certain ranges depending on PABX If the setting time of your PABX is less than 0 13 seconds Please set SYS_...

Страница 15: ...sic data EVM Programming for Specific PABXs PABX Operating way Function Code Others ALCTEL 4200 SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 SYS_45_ 2 LUCENT PROLOGIX SYS_54_ 3 SYS_55_ 3 SYS_56_ 3 NAKAYO 64IS 88IS S...

Страница 16: ...one SYS_75_ SYS_64_ SYS_55_ 1 No Answer ID Code Retrieving call No Answer Ring Back tone SYS_76_ SYS_63_ SYS_56_ 1 Operator No Hunting Port locked up Auto detection ADM_59940_ SYS_47_ 2 ADM_59941_ Pre...

Страница 17: ......

Отзывы: