JOHNSON CONTROLS
64
SECTION 5 - TECHNICAL DATA
FORM 201.28-NM1.1
ISSUE DATE: 1/31/2018
TABLE 5 -
PHYSICAL DATA - MICROCHANNEL COIL
The data shown in this table is applicable to select-
ed typical configurations. Other configurations are
available through our configuration/selection software.
Please contact your nearest Johnson Controls Sales
Office for the chiller configuration that best matches
your specific needs.
NOTES:
1. Shipping and operating weights shown are for base unit; selected options may add weight to unit. Contact your nearest Johnson Controls Sales
office for weight data.
2. For leaving liquid temperature below 40°F(4.4°C) or above 60°F (15.6°C), contact your nearest Johnson Controls Sales Office for application
requirements.
UNIT FRAME
15
16
17
18
19
19
20
21
21
21
UNIT FRAME
23
24
24
26
27
27
27
27
29
30
CONDENSER CODE
3
5
8
3
5
8
0
3
5
8
CONDENSER CODE
3
5
8
3
0
3
5
8
5
3
EVAPORATOR CODE
B
B
C
A
A
B
C
A
C
C
EVAPORATOR CODE
B
C
C
B
D
D
E
E
E
C
GENERAL UNIT DATA
GENERAL UNIT DATA
Number of Independent
Refrigerant Circuits
2
Number of Independent
Refrigerant Circuits
2
Refrigerant Charge,
R-134a, R-513A, Ckt.-1/
Ckt.-2, lbs (kg)
175/175
(79/79)
190/190
(86/86)
225/225
(102/102)
175/155
(79/70)
190/170
(86/77)
220/195
(100/88)
205/205
(93/93)
175/175
(79/79)
225/225
(102/102)
240/240
(109/109)
Refrigerant Charge,
R-134a, R-513A, Ckt.-1/
Ckt.-2, lbs (kg)
210/190
(95/86)
250/225
(113/102)
250/250
(113/113)
210/210
(95/95)
250/250
(114/114)
265/265
(120/120)
265/265
(120/120)
270/270
(122/122)
310/265
(141/120)
290/245
(132/111)
Oil Charge, Ckt.-1/Ckt.-2,
gal (liters)
2.1/2.0
(8.0/
7.7)
2.2/2.2
(8.5/
8.5)
2.5/2.5
(9.3/
9.3)
2.4/2.0
(9.2/
7.7)
2.6/2.1
(9.7/
8.0)
2.7/2.2
(10.4/
8.5)
2.6/2.6
(10.0/
10.0)
2.5/2.5
(9.3/
9.3)
2.8/2.8
(10.5/
10.5)
2.9/2.9
(10.8/
10.8)
Oil Charge, Ckt.-1/Ckt.-2,
gal (liters)
2.7/2.6
(10.1/
9.7)
2.9/2.8
(11.1/
10.5)
2.9/2.9
(11.1/
11.1)
2.7/2.7
(10.1/
10.1)
3.0/3.0
(11.4/
11.4)
3.0/3.0
(11.4/
11.4)
3.0/3.0
(11.4/
11.4)
3.1/3.1
(11.6/
11.6)
3.8/3.1
(14.4/
11.7)
3.7/3.0
(14.0/
11.4)
Minimum Load (%)
10%
Minimum Load (%)
10%
Chassis Dimensions -
Length, inches (mm)
203.3
(5163)
247.2
(6280)
291.2
(7397)
247
(6274)
291.2
(7397)
335.2
(8514)
226
(5741)
291.2
(7397)
291.2
(7397)
335.2
(8514)
Chassis Dimensions -
Length, inches (mm)
291.2
(7397)
335.2
(8514)
379.1
(9631)
335.2
(8514)
291.2
(7397)
335.2
(8514)
335.2
(8514)
379.2
(9631)
379.2
(9631)
379.2
(9631)
Chassis Dimensions -
Width, inches (mm)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
Chassis Dimensions -
Width, inches (mm)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
88.3
(2242)
Chassis Dimensions -
Height, inches (mm)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
Chassis Dimensions -
Height, inches (mm)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
94.6
(2403)
COMPRESSORS, SEMI-HERMETIC SCREW
COMPRESSORS, SEMI-HERMETIC SCREW
Qty per Chiller
2
Qty per Chiller
2
CONDENSER FANS
CONDENSER FANS
Number Ckt-1/Ckt-2
4/4
5/5
6/6
6/4
7/5
8/6
4/4
6/6
6/6
7/7
Number Ckt-1/Ckt-2
7/5
8/6
8/8
7/7
6/6
7/7
7/7
8/8
9/7
9/7
Air on Condenser
(Min/Max), °F (°C)
0/131
(-17.8/55)
Air on Condenser
(Min/Max), °F (°C)
0/131
(-17.8/55)
EVAPORATOR, SHELL AND TUBE HYBRID FALLING FILM
2
EVAPORATOR, SHELL AND TUBE HYBRID FALLING FILM
2
Water Volume, gal (liters)
58
(220)
58
(220)
71 (269)
48
(182)
48
(182) 58 (220)
71
(269)
48
(182)
71 (269) 71(269)
Water Volume, gal (liters) 58(220) 71(269) 71(269) 58(220) 82(310) 82(310) 113(428) 113(428) 113(428) 71(269)
Leaving Water
Temperature (Min/Max),
°F (°C) 3
40/60
(4.4/15.6)
Leaving Water
Temperature (Min/Max),
°F (°C) 3
40/60
(4.4/15.6)
Maximum Water Side
Pressure, psig (barg)
150
(10.3)
Maximum Water Side
Pressure, psig (barg)
150
(10.3)
Maximum Refrigerant
Side Pressure, psig
(barg)
235
(16.2)
Maximum Refrigerant
Side Pressure, psig
(barg)
235
(16.2)
Evap Drain Connection,
inches (mm)
3/4
Evap Drain Connection,
inches (mm)
3/4
Minimum Chilled Water
Flow Rate, gpm (l/sec)
250
(15.8)
250
(15.8)
300
(18.9)
200
(12.6)
200
(12.6)
250
(15.8)
300
(18.9)
200
(12.6)
300
(18.9)
300
(18.9)
Minimum Chilled Water
Flow Rate, gpm (l/sec)
250
(15.8)
300
(18.9)
300
(18.9)
250
(15.8)
300
(18.9)
300
(18.9)
400
(25.2)
400
(25.2)
400
(25.2)
300
(18.9)
Maximum Chilled Water
Flow Rate, gpm (l/sec)
950
(59.9)
950
(59.9)
1150
(72.6)
750
(47.3)
750
(47.3)
950
(59.9)
1150
(72.6)
750
(47.3)
1150
(72.6)
1150
(72.6)
Maximum Chilled Water
Flow Rate, gpm (l/sec)
950
(59.9)
1150
(72.6)
1150
(72.6)
950
(59.9)
1150
(72.6)
1150
(72.6)
1500
(94.7)
1500
(94.7)
1500
(94.7)
1150
(72.6)
Inlet and Outlet Water
Connections, in
6
6
6
6
6
6
6
6
6
6
Inlet and Outlet Water
Connections, in
6
6
6
6
6
6
8
8
8
6
Содержание YVAA
Страница 4: ...JOHNSON CONTROLS 4 FORM 201 28 NM1 1 ISSUE DATE 10 12 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 12: ...JOHNSON CONTROLS 12 FORM 201 28 NM1 1 ISSUE DATE 10 12 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 24: ...JOHNSON CONTROLS 24 FORM 201 28 NM1 1 ISSUE DATE 10 12 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 96: ...JOHNSON CONTROLS 96 FORM 201 28 NM1 1 ISSUE DATE 10 12 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 126: ...JOHNSON CONTROLS 126 FORM 201 28 NM1 1 ISSUE DATE 10 12 2017 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 174: ...JOHNSON CONTROLS 174 FORM 201 28 NM1 1 ISSUE DATE 1 31 2018 THIS PAGE INTENTIONALLY LEFT BLANK...
Страница 177: ...JOHNSON CONTROLS 177 FORM 201 28 NM1 1 ISSUE DATE 1 31 2018 NOTES...