Multi-function Output Settings: H2
Multi-function Output Settings: H2
Multi-function Output Functions
Setting
value
Function
Control Methods
V/f
V/f
w /
PG
Open
loop
Vector
Flux
vector
During run (ON: run command is ON or voltage is being output)
Zero-speed
Frequency agree 1: (Detection width L4-02)
Desired frequency agree 1 (ON: Output frequency = ± L4-01, detection width in L4-02)
Frequency (Four) detection 1 (ON: +L4-01
≥ output frequency ≥
−L4-01, detection width in L4-02)
Frequency (Four) detection 2
(ON: Output frequency
≥ +L4-01 or output frequency ≤
−L4-01, detection width in L4-02)
Inverter operation ready READY: After initialization, no faults
During DC bus undervoltage (UV) detection
During baseblock (ON: during baseblock)
Frequency reference selection (ON: Frequency reference from Operator)
Run command selection (ON: Run command from Operator)
Overtorque detection 1 NO (NO contact: Overtorque detection at ON)
Loss of frequency reference (Effective when operation selection is “1” for L4-05 frequency reference missing)
Braking resistor fault (ON: Resistor overheat or braking transistor fault)
Fault (ON: Faults other than CPF00, CPF01 have occurred.)
Not used.
Minor fault (ON: Alarm displayed)
Fault reset command active
Timer function output
Frequency agree 2 (Detection width: L4-04)
Desired frequency agree 2 (ON: Output frequency = L4-03, detection width in L4-04)
Frequency detection 3 (ON: Output frequency
≤
−L4-03, detection width in L4-04)
Frequency detection 4 (ON: Output frequency
≥
−L4-03, detection width in L4-04)
Overtorque detection 1 NC (NC Contact: Torque detection at OFF)
Overtorque detection 2 NO (NO Contact: Torque detection at ON)
Overtorque detection 2 NC (NC Contact: Torque detection at OFF)
During reverse run (ON: During reverse run)
During baseblock 2 (OFF: During baseblock)
Motor selection (Motor under selection)
Regenerating (ON: Regenerating)
Restart enabled (ON: Restart enabled)
Motor overload (OL1) pre-alarm (ON: 90% or more of the detection level)
Inverter overheat (OH) pre-alarm (ON: Temperature exceeds L8-02 setting)
During torque limit (current limit) (ON: During torque limit)
During speed reference limit. (ON: During speed reference limit)
Zero-servo end (ON: Zero-servo function completed)
During run 2 (ON: Frequency output, OFF: Base block, DC injection braking, initial excitation, operation stop.