Monitor Displays
Monitor Displays
The following notation is used in this manual when describing user constants.
Valid Access Levels
Valid Access Levels
Name
Name
Display
Display
Unit
Unit
V/f
V/f w/
PG
Open
-loop
Vec-
tor
Flux
Vec
-
tor
User
Constant
Number
User
Constant
Number
Monitor selection
Change during
Operation
Change during
Operation
Setting
Range
Setting
Range
Factory
Setting
Factory
Setting
Use the last two digits from the U1 Monitor list (U1-
□□
) to select a value. For example, the torque
reference
is U1-09, so input 9 to select the torque reference.
Indicates whether or not the constant can be changed during operation.
Change during
Operation
Can be changed during operation.
Cannot be changed during operation.
Setting Range
The setting range for the constant.
Units
The unit used to set the constant (“−” indicates that no unit is used).
Factory Setting
The value preset at the factory. (There are different factory settings for each control meth
od,i.e., if the control method is changed, the factory setting can also change.)
Indicates the control methods and access levels under which the constant can be accessed
and set.
Accessible/settable under all access levels (Quick-start, Basic, and Advanced).
Accessible/settable under Advanced or Basic access levels.
Accessible/settable under Advanced access level.
Not accessible/settable in the specified control method.
Monitor selection after
power up
Use constant o1-02 to indicate which value will be displayed when the Inverter is started. Refer to
the followingtable.
Monitor Display Contents at Startup
Setting
Contents
1
Indicates the frequency reference at startup.
2
Indicates the output frequency at startup.
3
Indicates the output current at startup.
4
Indicates the value set in user constant o1-01 at startup.
Setting
Contents
4
.
3
Procedure
4
.
3
Procedure
Perform trial operation according to the following operational flow.