Starting torque compensation is disabled when switching
between forward and reverse after conducting
a speed
search.Starting torque compensation is always disabled
when the second motor is used.
Set the constant for starting torque compensation (C4-
05) to a large value if a shock is generated duringstartup.
Alternatively, use DC injection braking (b2-03) at startup
or the DC braking command for multifunctioncontact
input (setting: 60), and start motor magnetic flux before
startup.
5
.
3
.
5Speed Control (ASR): C5
5
.
3
.
5Speed Control (ASR): C5
SettingRange
SettingRange
Function
Function
SettingRange
SettingRange
Function
Function
Description of choice
Description of choice
Sets the proportional gain of the speed
loop (ASR )
Description of choice
Description of choice
Sets the integral time of the speed loop(ASR) in 1 second units
SettingRange
SettingRange
Function
Function
Set ASR proportional gain 2 (C5-03) and ASR integral
time 2 (C5-04) for the minimum output frequency.
SettingRange
SettingRange
Function
Function
Function
Function
Description of choice
Description of choice
When using “V/f control with PG feedback,” set the gain
at the minimum output frequency and maximumoutput
frequency.
Set the proportional gain (C5-01) and the integral
time (C5-0
2) of the speed control (ASR)
Usually setting is not necessary.Set to change the rotational
speed gain.
Usually setting is not necessary.Set to change the rotational speed gain.
SettingRange
SettingRange
Sets the upper limit for the compensationfrequency for
t h e s p e e d c o n t ro l l o o p ( AS R ) t o a p e rc e n t a g e o f t h e
maximumoutput frequency.
Description of choice
Description of choice
Since C5-05 can’t be changed during operation, stop the
Inverter’s operation and then decreasethe ASR limit
by 0.5 (%).
Increase the setting can improve responsiveness, usually
a larger load is to increase the set value, but will occur
when the shock is too large
The ASR limit is the frequency limit for compensation by
speed control. Set this frequency limitas a percentage of the
maximum output frequency.
SettingRange
SettingRange
Function
Function
4
Sets the filter time constant; the time
from the speed loop to the
torque commandoutput in units of 1-secondmand output, second.
Description of choice
Description of choice
Normally it isn’t necessary to make this adjustment.
Constant C5-06 can be used when adjusting the gain
doesn’t remove
]
motor oscillation, or adjustingthe
gain removes oscillation but results in poor responsiv
-
eness.A high C5-06 setting lowers the responsiveness
of the speed control, but makes it difficult for oscillationto
occur.
SettingRange
SettingRange
Function
Function
Sets the frequency for switching betweenProportion
Gain 1, 2 and Integral Time 1,2 in Hz units
Set constant C5-07 to the frequency at which to switch
to the low-speed ASR proportional gain and
integral
time.
4
Set to a small value to prevent any radiC5cal load change.
Set to 100% of the max- maximum
output frequency.
4
4
5
.
3
.
6Carrier Frequency: C6
5
.
3
.
6Carrier Frequency: C6
Description of choice
Description of choice
Function
Function
SettingRange
SettingRange
Function
Function
Set the carrier frequency upper limit and
lower limit in kHz units.
SettingRange
SettingRange
Function
Function
SettingRange
SettingRange
Carrier frequency setting minimum
Khz unit limit
Function
Function
Set the carrier frequency upper limit and
lower limit in
kHz units.
SettingRange
SettingRange