![Yolico YD3000N Series Скачать руководство пользователя страница 83](http://html1.mh-extra.com/html/yolico/yd3000n-series/yd3000n-series_instruction-manual_3495948083.webp)
Output frequency
Upper limit
Lower limit
Accelerates to
lower limit
Same frequency
D4-01=1
D4-01=0
Forward/Stop
ON
Up command
ON
ON
Reference frequency reset
Down command
Speed Agree signal
ON
ON
Power supply
ON
The Speed Agree signal remains ON while the run command is ON and the motor isnot accelerating or decelerating.
Timing Chart for Up and Down Commands
Fault Reset (Setting: 14)
OFF
Normal operation
ON
Resets faults when input goes from OFF to ON. (Normal operation when no fault has occurred.)
With this setting, the multi-function input resets faults that have occurred.
When a fault has occurred, be sure to find out what kind of fault occurred, take steps to correct the
causeof the fault, and restart the Inverter. the Inverter by repeatedly resetting a fault
without
correcting the cause.To resume operation after a fault has occurred, turn the run command OFF,
turn the fault reset inputfrom ON to OFF, and then turn the run cannot be reset while the run command
is ON.If a fault hasn’t occurred, turning the fault reset ON and OFF will have no effect on operation.
Motor Switch Command (Motor 2 Selection, Setting: 16)
CLOSED: Motor 2 constants used.
Operation
Note Use an external sequence to switch between M1 and M2
and to confirm the motor selection status.
Motor Switch command
(CLOSED for motor 2)
U , V , W
(T1, T2, T3)
Motor 1 (main motor)
Motor 2 (auxiliary motor)
M1
M2
Multi-function input
Multi-function output
Motor selection monitor
(CLOSED for motor 2)
The control method, V/f characteristics, and motor constants recorded in the Inverter can beswitched by setting “16” (motor switch
command) for a constant from H1-01 to 06 (multi-function
inputs), and then inputting a signal while the motor is stopped.
The current motor selection can be monitored at a multi-function output terminal by setting “1C”
(motor selection monitor)
for a constant from H2-01 to 03 (multi-function outputs).
Is a registered trademark of yolico
YD3000N
نوﯾﺳﺎﻣوﺗا
ﯽﺗﻌﻧﺻ
ﮏﯾرﺗﮑﻟاوﺑار
قرﺑ
و
Содержание YD3000N Series
Страница 1: ...MULTI FUNCTION ALL DIGITAL TYPE YD3000N 630 YD3000 T4 N 69 0912 433 43 19 33 11 61 33 32...