Terminal 5
Terminal 6
Terminal 7
Terminal 8
Selected frequency
Multi-step speed
reference 1
Multi-step speed
reference 2
Multi-step speed
reference 3
JOG reference
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
-
-
-
Reference 1: d1-01 (master
speed frequency)
Reference 2: d1-02 (auxiliary
speed frequency)
Reference 3: d1-03
Reference 4: d1-04
Reference 5: d1-05
Reference 6: d1-06
Reference 7: d1-07
Reference 8: d1-08
Jog frequency: d1-09
Selecting 1-step and 2-step Frequency References
Selecting 1-step and 2-step Frequency References
To use the master frequency (analog terminal 13 or 14), set b1-01 to 1.
To use frequency reference 1 (d1-01), set b1-01 to 0.
To use the auxiliary frequency reference (analog terminal 16), use the factory setting.
To use frequency reference 2 (d1-02), set H3-05 to 1F.
Reference 1
Master speed
R e f e r e n c e 2
Auxiliary speed
Reference 3
Reference 4
Reference 5
Reference 6
Reference 7
Reference 8
JOG frequency
Frequency
reference
RUN/STOP
Multi-step speed reference 1
Multi-step speed reference 2
Multi-step speed reference 3
JOG reference
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
ON
Timing Chart for Multi-step Speed and JOG References