12-3
IM 704610-01E
Troubleshooting and
Maintenance
12
12.2 Error Code Description and Corrective Actions
Code
Message
Description and Corrective Action
Ref. section
148
Character data not allowed
<CHARACTER DATA> cannot be used.
10.2
Write in a data form other than {...|...|...}.
150
String data error
There is no delimiter to the right of <STRING DATA>.
10.1
Enclose <String data> in double quotation or single quotation
marks.
151
Invalid string data
The contents of <STRING DATA> are inappropriate.
10.2
<String data> is too long or invalid character is present.
158
String data not allowed
<STRING DATA> cannot be used.
10.2
Write in a data form other than <String data> form.
161
Invalid block data
The data length of <BLOCK DATA> does not match.
10.1, 10.2
<Block data> cannot be used.
168
Block data not allowed
<BLOCK DATA> cannot be used.
10.1, 10.2
171
Invalid expression
There is an invalid character in the <EXPRESSION DATA>.
10.2
Equation cannot be used.
178
Expression data not allowed
<EXPRESSION DATA> cannot be used.
10.2
Equations cannot be used.
181
Invalid outside macro definition
The placeholder is outside the macro.
—
IEEE488.2 macro function is not supported.
Error in communication execution
Code
Message
Description and Corrective Action
Ref. section
221
Setting conflict
Contradictory settings are in affect.
10,2
Check the relevant communication settings.
222
Data out of range
The value of <DATA> is outside the range. Check the range.
10,2
223
Too much data
The byte length of <DATA> is too long.
10,2
Check the length of data bytes.
224
Illegal parameter value
The value of <DATA> is inappropriate. Check the range.
10,2
241
Hardware missing
Hardware not installed.
—
Check for the presence or absence of options.
260
Expression error
<EXPRESSION DATA> is not correct. Equation cannot be used. —
270
Macro error
Macro nesting is too deep.
—
IEEE488.2 macro function is not supported.
272
Macro execution error
Macros cannot be used.
—
IEEE488.2 macro function is not supported.
273
Illegal macro label
The macro label is inappropriate.
—
IEEE488.2 macro function is not supported.
275
Macro definition too long
Macro is too long. IEEE488.2 macro function is not supported.
—
276
Macro recursion error
Macro was recursively called.
—
IEEE488.2 macro function is not supported.
277
Macro redefinition not allowed
Macros cannot be redefined.
—
IEEE488.2 macro function is not supported.
278
Macro header not found
The macro is not defined.
—
IEEE488.2 macro function is not supported.
708
Cannot output data while measuring
Cannot transmit data while measurement in progress.
10.2.13,
Stop the measurement using the STOP or SSTART command.
10.2.6