10-10
IM 704610-01E
10.2 Commands
Command
Function
Page
INPut Group
:INPut?
Queries all settings related to signal input.
10-21
:INPut:DATA?
Queries all settings related to signal input (excluding the equalizer).
10-21
:INPut:DATA:COUPling
Sets the input coupling or queries the current setting.
10-21
:INPut:DATA:IMPedance
Sets the input impedance or queries the current setting.
10-21
:INPut:DATA:POLarity
Sets the polarity of the data signal or queries the current setting.
10-21
:INPut:DATA:TRIGger?
Queries all settings related to the trigger.
10-21
:INPut:DATA:TRIGger:LEVel
Sets the trigger level (slice level) or queries the current setting.
10-21
:INPut:DATA:TRIGger:MODE
Sets the trigger mode or queries the current setting.
10-21
:INPut:EQ?
Queries all settings related to the equalizer.
10-21
:INPut:EQ:STATus
Sets the equalizer status or queries the current setting.
10-21
:INPut:EQ:BOOSt
Sets the boost amount of the equalizer or queries the current setting.
10-22
:INPut:EQ:AGC
Turns the equalizer’s AGC function ON and OFF or queries the current setting.
10-22
:INPut:EQ:DCCLamp
Turns the equalizer’s DC clamp function ON and OFF or queries the current
setting.
10-22
:INPut:EQ:PLLHold
Turns the equalizer’s PLL hold function ON and OFF or queries the current
setting.
10-22
:INPut:HISPeed:STATe
Sets the D-to-C high speed calculation function or queries the current setting.
10-22
:INPut:PLL:STATus?
Queries PLL lock status.
10-22
LVOut Group
:LVOut?
Queries all settings related to level measurement.
10-23
:LVOut:STATe
Turns level measurement ON or OFF or queries the current setting.
10-23
:LVOut:MODE
Sets the level measurement output mode or queries the current setting.
10-23
:LVOut:CYCLe
Sets the level measurement output filter average coefficient or queries the
current setting.
10-23
:LVOut:LEVel:RANGe
Sets the upper and lower limit of the level measurement output range or
queries the current setting.
10-23
:LVOut:JUDGe:LEVel
Sets the upper and lower limit of the level measurement output determination
level or queries the current setting.
10-24
:LVOut:JUDGe:RESult?
Queries the level measurement output determination results.
10-24
MEASure Group
:MEASure?
Queries all settings related to measurement conditions.
10-24
:MEASure:FUNCtion
Sets the measurement function or queries the current setting.
10-24
:MEASure:SPEed?
Queries the measurement speed.
10-24
MEMory Group
:MEMory?
Queries all settings related the external transmission of the measured data.
10-25
:MEMory:BYTeorder
Sets the transmission order of binary data or queries the current setting.
10-25
:MEMory:CLEar
Clears measured data.
10-25
:MEMory:DATaselect
Sets the data to be transmitted or queries the current setting.
10-25
:MEMory:END
Sets the position of the data to be transmitted or queries the current setting.
10-25
:MEMory:FORMat
Sets format of the data to send or queries the current setting.
10-25
:MEMory:SEND?
Executes the transmission of the measured data specified by
MEMory:DATaselect.
10-26
:MEMory:STARt
Sets the transmission start position of the data to be transmitted or queries
the current setting.
10-26
RECall Group
:RECall
Recalling setting information
10-26
SAMPle Group
:SAMPle?
Queries all settings related to sampling.
10-27
:SAMPle:ARMing?
Queries all settings related to arming.
10-27
:SAMPle:ARMing:DELay?
Queries all settings related to the arming delay.
10-28
:SAMPle:ARMing:DELay:TIME
Sets the arming delay time or queries the current setting.
10-28
:SAMPle:ARMing:SLOPe
Sets the arming slope or queries the current setting.
10-28