5-32
IM XL100C-E
GROUP key:
GROUP
MARK key:
MARK
MARK left key:
MARKLEFT
MARK right key:
MARKRIGHT
SET key:
SET
START/STOP key:
STARTSTOP
Up arrow key:
UP
Down arrow key:
DOWN
Right arrow key:
RIGHT
Left arrow key:
LEFT
SELECT key:
SELECT
Example
Press the DISPLAY key.
KE DISP
Description Operates in the same fashion as the key
operation on the XL100. For consecutive key
operations, transmit the commands in the same
order as the key operation on the XL100.
BZ
Sets the activation of the setting
commands.
Syntax
BZ p1<terminator>
p1
Activation method of setting commands
Activate after the setting command is
executed (default):
1
Activate when the settings are saved using
the XE command after executing the setting
command:
0
Query
BZ?
Example
Activate the setting commands when the settings
are saved using the XE command as with basic
setting commands.
BZ 0
Description • The default setting (the response to BZ? is BZ
1) is always in effect at power-on.
• This command is activated immediately.
5.7
Basic Setting Commands
• In order to activate the settings that are changed
using the basic setting commands, the settings
must be saved using the XE command.
The settings that are returned in response to a
query after issuing a basic setting command are the
new settings even if the settings have not been
saved with the XE command. However, the new
settings only take effect after saving the settings
using the XE command.
If you discard the settings with the XE command or
start the logging operation before saving the
settings with the XE command, the settings that are
returned in response to a query are reset to those
before the change.
• Basic setting commands cannot be used to change
settings while logging is in progress.
XA
Sets the alarm
Syntax
XA
p1,p2,p3,p4,p5,p6,p7,p8,p9<terminator>
p1
Reserved
p2
Output number to be set to AND
For all ORs:
NONE
Independent setting:
I01
,
I02
,
I03
, or
I04
Range setting:
I0x-I0y
(I0x,I0y:I01 to I04)
Multiple settings (delimit using a period):
I0w.I0y.I0z
(I0w,I0y,I0z:I01 to
I04)
p3
Reserved
p4
Output hold/non-hold
Hold:
HOLD
Non-hold:
NONHOLD
p5
Hold/Not hold the alarm status display
Hold:
HOLD
Non-hold:
NONHOLD
p6
Reserved
p7
Reserved
p8
Alarm hysteresis ON/OFF:
ON
or
OFF
p9
Alarm buzzer ON/OFF:
ON
,
OFF
Query
XA?
Example
Set output numbers I01 to I04 to AND, hold the
output, hold the alarm status display, turn the
alarm hysteresis ON, and turn the alarm buzzer
ON.
XA ,I01-I12,HOLD,HOLD,,,ON,ON
Description Parameters p1, p3, p6, and p7 are not used.
XI
Sets the filter.
Syntax
XI p1<terminator>
5.6 Setting Commands (Control)/5.7 Basic Setting Commands