background image

EN

SENECA s.r.l. 

Via Austria, 26 - 35127 - PADOVA 

– ITALY

Tel. +39.049.8705355  - 8705359 - Fax +39.049.8706287

For manuals and configuration software, go to www.seneca.it/prod

uc

t

s

/z-umts

This document is the property of SENECA srl. Copies and reproduction are prohibited unless authorised. 
The content of this document corresponds to the described products and technologies. 
Stated data may be modified or supplemented for technical and/or sales purposes.

MI00499-1-EN

INSTRUCTIONS IN ORIGINAL LANGUAGE

ENGLISH - 1/8

INSTALLATION MANUAL

Z-UMTS 

HW2

HSPA data with built-in I/O, remote control functions 

built-in UPS, GPS and advanced programming

Содержание Z-UMTS HW2

Страница 1: ...rl Copies and reproduction are prohibited unless authorised The content of this document corresponds to the described products and technologies Stated data may be modified or supplemented for technical and or sales purposes MI00499 1 EN INSTRUCTIONS IN ORIGINAL LANGUAGE ENGLISH 1 8 INSTALLATION MANUAL Z UMTS HW2 HSPA datalogger with built in I O remote control functions built in UPS GPS and advanc...

Страница 2: ... level 1 n 1 flash poor Green Off GSM level 0 no signal MOD Yellow On n Registered on 3G 3G network Off Other GSM STATUS Yellow Slow flashing 0 2s ON n 1 8s OFF n 200ms High 1800ms Low Network search Slow flashing 1 8s ON n 0 2s OFF nnnnnnnnn 1800ms High 200ms Low Connected Fast flashing 0 125s ON n0 125s OFF n n n n n n n n 125ms High 125ms Low Data transfer in p rogress On n Voice call MODULE LA...

Страница 3: ... closed to 12V Off Digital Input 2 Not energised contact open DI3 Red ON NPN Digital Input 3 Energised contact closed to GND ON PNP Digital Input 3 Energised contact closed to 12V Off Digital Input 3 Not energised contact open DI4 Red ON NPN Digital Input 4 Energised contact closed to GND ON PNP Digital Input 4 Energised contact closed to 12V Off Digital Input 4 Not energised contact open PWR Gree...

Страница 4: ...ile communications EN301 489 1 Electromagnetic compatibility for mobile radio equipment EN301 489 7 Specific conditions EMC for mobile radio equipment EN60950 Security in information processing equipment INSULATION ENVIRONMENTAL CONDITIONS Temperature Humidity Storage temperature Protection rating 10 50 C 10 40 C if the internal UPS is used 30 90 non condensing 20 65 C 20 45 C 6 months if the inte...

Страница 5: ... M11 M12 Ethernet 10 100 baseT with autoswitch on front RJ45 socket and USB on microB side socket 3G WORLD WIDE PENTABAND MODEM GSM GPRS EDGE WCDMA HSDPA HSUPA HSPA DC HSPA SUPPORTED PROTOCOLS FTP client SMTP client http rest SSL MQTT SSL ModBUS TCP server ModBUS TCP client ModBUS RTU master ModBUS RTU slave For further information refer to the User Manual GNSS 8th generation 16 GPS channels 14 GL...

Страница 6: ...bstructing ventilation slots with any object is prohibited Installing the module next to devices that generate heat is prohibited Electrical and electronic waste disposal applicable in the European Union and other countries with recycling The symbol on the product or its packaging shows that the product must be disposed of at a collection centre authorised to recycle electrical and electronic wast...

Страница 7: ... use shielded signal cables connect the shield to a preferential instrumentation earth system separate shielded cables from other cables used for power installations transformers inverters motors induction ovens etc POWER SUPPLY The power supply must be connected to terminals 2 and 3 The supply voltage must be between 19 and 40Vdc indifferent polarity or between 19 and 28 Vac The upper limits must...

Страница 8: ...als 10 11 12 INSERTING THE SIM CARD AND SD CARD Inserting the SIM into the rear slot next to the IDC10 connector Inserting the microSD or microSHDC card into the side slot MAX 32 GB Push push connector SETTINGS DIP SWITCHES SW1 All DIP switches in OFF position For further information refer to the USER MANUAL SW2 RS232 or RS485 configuration on terminals 10 11 12 COM 2 serial port RS232 ON RS485 OF...