User's Guide
CO
2
/Humidity/Temperature Datalogger
Model SD800
Страница 1: ...User s Guide CO2 Humidity Temperature Datalogger Model SD800 ...
Страница 2: ...Carbon Dioxide Temperature and Relative Humidity Datalogger date time stamps and stores readings on an SD card in Excel format for easy transfer to a PC Selectable data sampling rate 5 10 30 60 120 300 600 seconds Product Description 1 Humidity Temperature Sensor 2 Humidity Display 3 Temperature Display 4 CO2 Display 5 LOG ENTER button 6 SET button 7 AC adaptor socket 8 CO2 probe socket 9 TIME but...
Страница 3: ...advanced features section of this manual to set the clock Note The default data structure uses a decimal point as the numeric decimal indicator See the advanced features section of this manual to change this to a comma Note If the SD memory card is not installed EMPTY will appear in the display Note Displayed error messages The memory card is full or there is a problem with the card The battery is...
Страница 4: ...0 000 3 After 30 000 columns a new file CHA01002 XLS is created This is repeated every 30 000 columns until CHA01099 XLS At this point a new folder CHA02 is created and the process is repeated CHA10 is the final folder Transferring Data to a PC 1 Remove the memory card from the datalogger and plug it into the SD card slot on the PC 2 Launch Excel and open the data file on the memory card from with...
Страница 5: ... seconds and AUTO In AUTO the data will be stored every time there is a temperature change of 1 degree 1 RH or 50 ppm 5 bEEP Set the beeper ON or OFF Press the button to select ON or OFF and press Enter to store the selection 6 dEC Set the SD card Decimal character Press the button to select USA decimal or Euro comma and press Enter to store the selection 7 t CF Set the Temp unit to F or C and pre...
Страница 6: ...off the cover 2 Replace the six AAA batteries use alkaline heavy duty type observing polarity 3 Replace and secure the cover 4 You as the end user are legally bound EU Battery ordinance to return all used batteries disposal in the household garbage is prohibited You can hand over your used batteries accumulators at collection points in your community or wherever batteries accumulators are sold Dis...
Страница 7: ...P s b l 3 5 0 g 0 4 2 r e t e M t h g i e W Dimension Meter 132 x 80 x 32mm 5 2 x 3 1 x 1 3 Probe 132 x 38 x 32mm 5 2 x 1 5 x 1 3 Range Resolution Accuracy 0 0 to 50 0 C 0 1 C 0 8 C Temperature 32 0 to 122 0 F 0 1 F 1 8 F H R 4 0 7 o t 0 1 Relative Humidity 70 to 90 0 1 4 of reading 1 RH m p p 0 4 m p p 0 0 0 1 1000 to g n i d a e r f o 5 m p p 0 0 0 3 CO2 3000ppm 1ppm 250ppm typical Note Above sp...