5-75
IM DLM4038-17EN
Commands
1
2
3
4
5
6
App
Index
:ANALysis:PMEAsure<x>:MEASure?
Function
Queries all the settings for automated
measurement of power measurement
parameters.
Syntax
:ANALysis:PMEAsure<x>:MEASure?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE?
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>?
Function
Queries the setting of a power measurement
parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE:AH?
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:COUNt?
Function
Queries the normal statistical processing count of
the power measurement parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:COUNt?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE:AH:COU
NT?
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:{MAXimum|MEAN|MINimum|SDEViati
on}?
Function
Queries a statistical value of a power
measurement parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:{MAXimum|MEAN|MINimum|SDEViati
on}?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE:AH:MAXIM
UM?
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:STATe
Function
Queries the on/off status of the power
measurement parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:STATe {<Boolean>}
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:STATe?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE:AH:STA
TE ON
:ANALYSIS:PMEASURE1:MEASURE:AH:STA
TE?
-> :ANALYSIS:PMEASURE1:MEASURE:AH:ST
ATE 1
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:VALue?
Function
Queries an automatically measured value of a
power measurement parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:<Param
eter>:VALue?
<x> = 1 to 4
<Parameter> =
{AH|AHABs|AHN|AHP|IAC|
IAVGfreq|IDC|IMN|INPeak|IPPeak|
IPTopeak|IRMN|IRMS|LAMBda|P|Q|S|UAC|
UAVGfreq|UDC|UMN|UNPeak|UPPeak|
UPTopeak|URMN|URMS|WH|WHABs|WHN|WHP|
Z}
Example
:ANALYSIS:PMEASURE1:MEASURE:AH:VAL
UE?
:ANALysis:PMEAsure<x>:MEASure:ALL
Function
Collectively turns on or off the power
measurement parameter.
Syntax
:ANALysis:PMEAsure<x>:MEASure:ALL {<
Boolean>}
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MEASURE:ALL ON
:ANALysis:PMEAsure<x>:MODE
Function
Sets or queries the on/off status of power
measurement.
Syntax
:ANALysis:PMEAsure<x>:MODE {<Boolean
>}
:ANALysis:PMEAsure<x>:MODE?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:MODE ON
:ANALYSIS:PMEASURE1:MODE?
-> :ANALYSIS:PMEASURE1:MODE 1
:ANALysis:PMEAsure<x>:RANGe
Function
Sets or queries the measurement source window.
Syntax
:ANALysis:PMEAsure<x>:RANGe {MAIN|
Z1|Z2}
:ANALysis:PMEAsure<x>:RANGe?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:RANGE MAIN
:ANALYSIS:PMEASURE1:RANGE?
-> :ANALYSIS:PMEASURE1:RANGE MAIN
:ANALysis:PMEAsure<x>:SETup?
Function
Queries all power measurement input settings.
Syntax
:ANALysis:PMEAsure<x>:SETup?
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:SETUP?
:ANALysis:PMEAsure<x>:SETup:ADESkew
Function
Executes auto deskewing for power
measurement.
Syntax
:ANALysis:PMEAsure<x>:SETup:ADESkew
<x> = 1 to 4
Example
:ANALYSIS:PMEASURE1:SETUP:ADESKEW
5.3 ANALysis Group