8. OPERATION VIA HART CONFIGURATION TOOL (HART 5)
This Chapter describes the device (AXR) operation
procedures using a HART configuration Tool (such
as FieldMate).
NOTE
For more details regarding the operations for
the HART configuration tool, read the HART
configuration tool operations manual.
Note: HART is a registered trademark of the
FieldComm Group.
8.1 HART Protocol Revision
For the models with the output signal code “-J”,
HART protocol revision 5 or 7 is selectable. The
protocol revision is set as specified in the order.
How to confirm protocol revision is shown below.
There are two ways to confirm the protocol revision
set to the transmitter.
(1) Confirmation by the name plate
The HART protocol revision at the time of
shipment is shown by the last number at the
serial number column of the name plate.
F0801.ai
XXX…XX
5: HART 5
7: HART 7
(2) Confirmation by using HART configuration tool
Read Subsection 8.8.5.
IMPORTANT
Protocol revision supported by HART
configuration tool must be the same or higher
than that of the device.
Protcol revision
supported by HART
configuration tool
5
7
Protocol revision of
the device
5
7
×
: Communication OK
×
: Communication NG
NOTE
In this User’s Manual, HART protocol revision
5 and 7 are described as HART 5 and HART 7
respectively.
NOTE
When the output signal code of the device is “-J”,
HART protocol revision can be changed. Read
Subsection 8.8.5 about the procedure of the
revision change of HART 5 and HART 7.
8.2 Device Description (DD) on
a HART Configuration Tool
and AXR Device Revision
8.2.1 DD Revision and Device Revision
Before using the HART Configuration Tool (such
as FieldMate), confirm that the DD (Device
Description) of the AXR is installed in the
Configuration Tool.
• AXR: HART 5
• Device type: 0x57
• Device Revision: 2
• DD Revision: 2
The DD revisions for AXR and Configuration Tool’s
can confirm in accordance with the following steps.
If the correct DD is not installed in the HART
Configuration Tool, download them from the HART
official site, otherwise, contact the respective
vendors of the Configuration Tool for its upgrade
information.
1. Confirmation of the device revision for AXR
(1) Connect the Configuration Tool to the AXR.
The device revision can be checked as
follows.
DD
Device Setup → Review → Review4
→ Fld dev rev
2. Confirmation of the device revision for the
HART Configuration Tool
(1) Turn on the power of the Configuration Tool
under the standalone condition.