Connection
5
-
50
5. Connect a ground wire to reduce noise and prevent electric shock.
Connect the ground wire to the ground terminal (screw) which is on the upper left side
of YRC1000.
Perform grounding in accordance with all relevant local and national electrical codes.
The size of ground wire must the same as listed on table Tab. 5-1: "YRC1000 Power
capacity, cable sizes, and breaker capacities"”.
NOTICE
Observe also local regulations.
6. Connect the primary power supply cable.
7. Install the cover.
Grounding terminal (M6 screws)
Grounding wire
Robot controller
Maximum earthing resistance of 0.1
Ω
to DIN EN
ISO 60204-1
1
2
1
2
Содержание YRC1000
Страница 1: ...ROBOTICS Instructions Robot controller User manual ...
Страница 30: ...Supply 3 30 Hood for CEE connector Covers ...
Страница 51: ...Connection 5 51 8 Close the YRC1000 door ...
Страница 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Страница 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Страница 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Страница 230: ...System Setup 9 230 4 Select the unit Or select the unit from DISPLAY in the menu For example COOLING FAN is selected ...
Страница 453: ...Description of Units and Circuit Boards 15 453 ...