System Backup
10
-
336
10.2
Backup by CMOS.BIN
Perform the backup by CMOS.BIN in the MAINTENANCE mode.
The chart below shows the availability of CMOS save / CMOS load in each SECURITY
mode in the MAINTENANCE mode.
10.2.1
CMOS.BIN save
Follow the procedures below to save CMOS.BIN.
1. Turn ON the robot controller power supply while pressing [MAIN MENU].
2. Insert a SD card into the SD card slot on the programming pendant.
When USB memory is used instead of SD card, mount USB memory and select one
among “USB: PENDANT”, “USB1: CONTROLLER” and “USB2: CONTROLLER” in the
{DEVICE}.
3. Select {EX. MEMORY} under the main menu.
The sub menu appears.
4. Select {SAVE}.
The items marked with "
" can not be selected.
The save display appears.
Security
CMOS save
CMOS load
OPERATION MODE
O
X
EDITING MODE
O
X
MANAGEMENT MODE
O
O
SAFETY MODE
O
O