Description of Units and Circuit Boards
15
-
402
15 Description of Units and Circuit Boards
•
Cautions for connection of dual input signals.
Please follow the safety instructions in chapter 2 "Safety" on page 15.
CAUTION!
Connect the switch (contact), which at the same time switches the 2-channel signals ON
and OFF.
If the timing that turns the two signals ON and OFF is not right, a disagreement alarm
occurs.
CAUTION!
Damage to property caused by short-circuit
As power supply is reversed for each signal, a short-circuit and thus a possible a robot
control failure occurs.
Do not connect the two signals to the same contact (use two separate contacts).
An alarm occurs due to the judgment of the safety circuit
Robot controller
Connection of 2-channel inputs
Input for the robot system
Turn ON/OFF at the same time
Input signal 1
Input signal 2
Switch
Robot controller
Connecting 2-channel inputs to the same
contact
Input for the robot system
Input signal 1
Input signal 2
Short circuit current
The same contact
Switch
1
2
3
4
5
6
1
2
3
4
5
6
7
Содержание YRC1000
Страница 1: ...ROBOTICS Instructions Robot controller User manual ...
Страница 30: ...Supply 3 30 Hood for CEE connector Covers ...
Страница 51: ...Connection 5 51 8 Close the YRC1000 door ...
Страница 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Страница 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Страница 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Страница 230: ...System Setup 9 230 4 Select the unit Or select the unit from DISPLAY in the menu For example COOLING FAN is selected ...
Страница 453: ...Description of Units and Circuit Boards 15 453 ...