System Setup
9
-
108
2. Press [FWD] again.
–
Press [FWD] again, and measurement of B-axis 1 and B-axis 2 starts.
The robot moves in the order listed below. Once measurement is completed, “
○
”
changes to “
●
”.
1) Measurement of the B-axis 1: B-axis home po30 degrees
→
-30 degrees
2) Move to the measurement position of B-axis 2
3) Measurement of the B-axis 2: B-axis home po30 degrees
→
-30 degrees
When the measurement is completed, the measured data appears on the screen.
NOTICE
During the measurement, the [FWD] button must be kept pressed. If the button is
released during the measurement or if it is released before “
○
” changes into “
●
”, the
measurement is aborted and the following message appears.
“Stopped measurement” The measurement starts again from the home position1.
3. Press [FWD].
Press [FWD], and the manipulator moves to the home position 2
(R-axis: rotating axis of B-axis is horizontal to the ground, B-axis: vertical to the ground).
NOTICE
If the tool is interfered with during the measurement, operate the S-, L- and T-axes and
move the manipulator to avoid the interference. Then move the axis to the home position 2.
Содержание YRC1000
Страница 1: ...ROBOTICS Instructions Robot controller User manual ...
Страница 30: ...Supply 3 30 Hood for CEE connector Covers ...
Страница 51: ...Connection 5 51 8 Close the YRC1000 door ...
Страница 142: ...System Setup 9 142 6 Select YES All data of the interference signal number is deleted ...
Страница 174: ...System Setup 9 174 7 Press ENTER The speed is modified ...
Страница 219: ...System Setup 9 219 4 Select GRAPH The graph appears 4 5 6 7 8 9 10 1 2 3 ...
Страница 230: ...System Setup 9 230 4 Select the unit Or select the unit from DISPLAY in the menu For example COOLING FAN is selected ...
Страница 453: ...Description of Units and Circuit Boards 15 453 ...