7 EtherNet/IP Configuring Messaging
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
37
7
EtherNet/IP Configuring Messaging
This section provides information on methods used to control the drive and converter with the option installed.
◆
Drive Polled Configuration
The assemblies in
are available for polled I/O:
Note:
These assemblies are not available in D1000 and R1000.
Table 7.1 Supported Polled I/O Assemblies
Assembly
Number
(Hex.)
Description
Type
Bytes
Page
20 (14)
EtherNet/IP Basic Speed Control Output
Output
4
21 (15)
EtherNet/IP Extended Speed Control Output
Output
4
22 (16)
EtherNet/IP Speed and Torque Control Output
Output
6
23 (17)
EtherNet/IP Extended Speed and Torque Control Output
Output
6
70 (46)
EtherNet/IP Basic Speed Control Input
Input
4
71 (47)
EtherNet/IP Extended Speed Control Input
Input
4
72 (48)
EtherNet/IP Speed and Torque Control Input
Input
6
73 (49)
EtherNet/IP Extended Speed and Torque Control Input
Input
6
100 (64)
(Vendor Specific Yaskawa Electric (YE) Assy) MEMOBUS Message Output
Output
5
101 (65)
(Vendor Specific Yaskawa Electric (YE) Assy) Speed/Torque Control Output
Output
8
115 (73)
(Vendor Specific Yaskawa Electric (YE) Assy) Extended Speed/Torque Control Output
Output
40
116 (74)
(Vendor Specific Yaskawa Electric (YE) Assy) High Speed/Torque Control Output
Output
44
117 (75)
(Vendor Specific Yaskawa Electric (YE) Assy) 8-Byte Dynamic Output
Output
8
118 (76)
(Vendor Specific Yaskawa Electric (YE) Assy) 12-Byte Dynamic Output
Output
12
119 (77)
(Vendor Specific Yaskawa Electric (YE) Assy) 18-Byte Dynamic Output
Output
18
120 (78)
(Vendor Specific Yaskawa Electric (YE) Assy) 24-Byte Dynamic Output
Output
24
150 (96)
(Vendor Specific Yaskawa Electric (YE) Assy) MEMOBUS Message Input
Input
5
151 (97)
(Vendor Specific Yaskawa Electric (YE) Assy) Speed/Torque Status Input
Input
8
155 (9B)
(Vendor Specific Yaskawa Electric (YE) Assy) Extended Speed/ Torque Status Input
Input
40
166 (A6)
(Vendor Specific Yaskawa Electric (YE) Assy) High Speed/Torque Status Input
Input
44
167 (A7)
(Vendor Specific Yaskawa Electric (YE) Assy) 8-Byte Dynamic Input
Input
8
168 (A8)
(Vendor Specific Yaskawa Electric (YE) Assy) 12-Byte Dynamic Input
Input
12
169 (A9)
(Vendor Specific Yaskawa Electric (YE) Assy) 18-Byte Dynamic Input
Input
18
170 (AA)
(Vendor Specific Yaskawa Electric (YE) Assy) 24-Byte Dynamic Input
Input
24
◆
Converter Polled Configuration
The assemblies in
are available for polled I/O:
Note:
These assemblies apply to D1000/R1000 converters.
Table 7.2 Supported Polled I/O Assemblies
Assembly
Number
(Hex.)
Description
Type
Bytes
Page
20 (14)
EtherNet/IP Basic Speed Control Output
Output
4
21 (15)
EtherNet/IP Extended Speed Control Output
Output
4
22 (16)
EtherNet/IP Speed and Torque Control Output
Output
6
23 (17)
EtherNet/IP Extended Speed and Torque Control Output
Output
6