13 General Class Objects (Converter)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
107
Instance ID
Attribute
Name
Description
Get
Set
Size
Range
Default
1: Force Run
1
9
Ready
Ready
0: Not Ready
1: Ready
○
-
Byte
-
1
1
10
Faulted
Faulted
0: No Fault
1: Fault
○
-
Byte
-
0
1
11
Alarm
Alarm
0: No Alarm
1: Alarm
○
-
Byte
-
0
1
12
Fault Reset
Fault Reset
0: -
1: Fault Reset
○
○
Byte
0, 1
0
1
13
Fault Code
Current Fault
Refer to page
for more
information.
○
-
Word
-
0000
1
15
NetCtrl (Status)
Run command is from network
0: Run command is not from
network
1: Run command is from network
○
-
Byte
-
0
1
16
EtherNet/IP Fault Mode
Normal 2 (Vendor Specific)
○
-
Byte
-
2
1
17
Force Fault
External Fault
0: -
1: External Fault [EF0]
Triggered by the rising edge of the
signal.
○
○
Byte
0, 1
0
1
18
Force Reset
External Fault status
0: -
1: External Fault [EF0]
Triggered by the rising edge of the
signal.
○
-
Byte
-
0
1
20
Net Idle Mode
Operation mode selection when
communication is in Idle Mode.
0: Stop
1: Ignore
2: Stop if F6-01 is set to fault
mode.
3: Forward Run
4: Reverse Run
Note:
Available in option software
versions PRG: 0345 and later.
○
○
-
0 - 4
◆
AC/DC Drive Object - 42 (Class 0x2A)
■
Services Supported
Service Code No. (Hex.)
Service Name
0E
Get Attribute Single
10
Set Attribute Single
■
Attributes Supported
Instance ID
Attribute
Name
Description
Get
Set
Size
Range
Default
0
1
Object Software Revision
Revision number of AC/DC drive
object
○
-
Word
-
1
1
4
NetRef (Command)
Voltage command is from network
0: Voltage command is not from
network
1: Voltage command is from
network
○
-
Byte
-
0
1
6
Drive Mode
Control Mode
0: Vendor Specific Control Mode
○
○
Byte
0
0
1
7
Voltage Actual
Voltage read from
U1-52 [DC Bus
DC Bus Voltage]
.
○
-
Word
-
-