12 General Class Objects (Drive)
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
97
Instance ID
Attribute
Name
Description
Get
Set
Size
Range
Default
1
18
Force Reset
External Fault status
0: -
1: External Fault [EF0]
Triggered by the rising edge of the
signal.
○
-
Byte
-
0
1
20
Net Idle Mode
Operation mode selection when
communication is in Idle Mode.
0: Stop
1: Ignore
2: Stop if F6-01 is set to fault
mode.
3: Forward Run
4: Reverse Run
Note:
Available in option software
versions PRG: 0345 and later.
○
○
-
0 - 4
■
Option Fault Code Conversion Table
Drive Fault Code (Dec.)
(MEMOBUS/Modbus 0080 (Hex.))
Option Fault Code (Hex.)
Description
0
0000
Normal
2
3220
Uv1 [DC Bus Undervoltage]
3
5110
Uv2 [Control Power Undervoltage]
4
3222
Uv3 [Soft Charge Answerback Fault]
6
2120
GF [Ground Fault]
7
2300
oC [Overcurrent]
8
3210
ov [Overvoltage]
9
4200
oH [Heatsink Overheat]
10
4210
oH1 [Heatsink Overheat]
11
2220
oL1 [Motor Overload]
12
2200
oL2 [Drive Overload]
13
2221
oL3 [Overtorque Detection 1]
14
2222
oL4 [Overtorque Detection 2]
15
7110
rr [Dynamic Braking Transistor Fault]
16
7112
rH [Braking Resistor Overheat]
17
9000
EF3 [External Fault (Terminal S3)]
18
9000
EF4 [External Fault (Terminal S4)]
19
9000
EF5 [External Fault (Terminal S5)]
20
9000
EF6 [External Fault (Terminal S6)]
21
9000
EF7 [External Fault (Terminal S7)]
22
9000
EF8 [External Fault (Terminal S8)]
24
7310
oS [Overspeed]
25
7310
dEv [Speed Deviation]
26
7301
PGo [Encoder (PG) Feedback Loss]
27
3130
PF [Input Phase Loss]
28
3130
LF [Output Phase Loss]
29
5210
oH3 [Motor Overheat (PTC Input)]
30
5300
oPr [Keypad Connection Fault]
31
6320
Err [EEPROM Write Error]
32
0
oH4 [Motor Overheat Fault (PTC Input)]
33
7500
CE [Modbus Communication Error]
34
7500
bUS [Option Communication Error]
37
8321
CF [Control Fault]