8 Output Assemblies (Drive Consumes)
48
YASKAWA
SIEP C730600 0DB EtherNet/IP Technical Manual
Name
Description
External Fault
External Fault EF0
0: -
1: External Fault [EF0]
Fault Reset
Fault Reset
0: -
1: Fault Reset
Multi-Function Digital Output 1
Terminal M1/M2 (varies by drive model)
0: M1/M2 OFF
1: M1/M2 ON
This function is enabled only when H2-01 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Multi-Function Digital Output 2
Terminal M3/M4 (varies by drive model)
0: M3/M4 OFF
1: M3/M4 ON
This function is enabled only when H2-02 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Multi-Function Digital Output 3
Terminal M5/M6 (varies by drive model)
0: M5/M6 OFF
1: M5/M6 ON
This function is enabled only when H2-03 is set to F.
Note:
The names of the digital outputs are different for different drive series.
Speed Reference
Speed Command
Sets drive speed reference.
Unit is min
-1
or determined by o1-03.
Unit is not affected by Speed Scale SS.
Dynamic Outputs
Contains the data to be written to the MEMOBUS/Modbus address defined in the given parameter. A value of 0 in the given
parameter means it is not used, therefore the value received for this given parameter will not be written to any MEMOBUS/
Modbus register. If the PPA is Input Assembly 166, then any errors occurring during a write will be flagged. Refer to page
for more information.
◆
(Vendor Specific Yaskawa Electric (YE) Assy) 18 Byte Dynamic Output - 119
(0x77)
Output Instance
Word
Byte
Bit 7
Bit 6
Bit 5
Bit 4
Bit 3
Bit 2
Bit 1
Bit 0
119
0
0
Multi-
Function
Input 8
Multi-
Function
Input 7
Multi-
Function
Input 6
Multi-
Function
Input 5
Multi-
Function
Input 4
Multi-
Function
Input 3
Run Rev
Run Fwd
1
Multi-
Function
Digital
Output 3
Multi-
Function
Digital
Output 2
Multi-
Function
Digital
Output 1
-
-
-
Fault Reset
External Fault
1
2
Speed Reference (Low Byte)
3
Speed Reference (High Byte)
2
4 - 5
Dynamic Output 1 [F7-23], Default: Not Used
3
6 - 7
Dynamic Output 2 [F7-24], Default: Not Used
4
8 - 9
Dynamic Output 3 [F7-25], Default: Not Used
5
10 - 11
Dynamic Output 4 [F7-26], Default: Not Used
6
12 - 13
Dynamic Output 5 [F7-27], Default: Not Used
7
14 - 15
Dynamic Output 6 [F7-28], Default: Not Used
8
16 - 17
Dynamic Output 7 [F7-29], Default: Not Used
Name
Description
Run Fwd
Forward Run Command
0: Stop
1: Forward Run
Run Rev
Reverse Run Command
0: Stop
1: Reverse Run
Multi-Function Input 3
Terminal S3 Function Input