1.3 SERVOPACK Ratings and Specifications
1-3
1
Ou
tline
1.3
SERVOPACK Ratings and Specifications
This section describes the ratings and specifications of SERVOPACKs.
1.3.1
Ratings
Ratings of SERVOPACKs are as shown below.
(1) SGDV with Single-phase, 100-V Rating
∗
Refer to
3.7 Connecting Regenerative Resistors
for details.
(2) SGDV with Single-phase, 200-V Rating
∗1.
The official model number is SGDV-120A11A008000.
∗2.
Refer to
3.7 Connecting Regenerative Resistors
for details.
(3) SGDV with Three-phase, 200-V Rating
∗
Refer to
3.7 Connecting Regenerative Resistors
for details.
SGDV (Single Phase, 100 V)
R70
R90
2R1
2R8
Continuous Output Current [Arms]
0.66
0.91
2.1
2.8
Instantaneous Max. Output Current [Arms]
2.1
2.9
6.5
9.3
Regenerative Resistor *
None or external
Main Circuit Power Supply
Single-phase, 100 to 115 VAC, +10% to -15%, 50/60 Hz
Control Power Supply
Single-phase, 100 to 115 VAC, +10% to -15%, 50/60 Hz
Overvoltage Category
III
SGDV (Single Phase, 200 V)
120
*1
Continuous Output Current [Arms]
11.6
Instantaneous Max. Output Current [Arms]
28
Regenerative Resistor
*2
Built-in or external
Main Circuit Power Supply
Single-phase, 220 to 230 VAC, +10% to -15%, 50/60 Hz
Control Power Supply
Single-phase, 220 to 230 VAC, +10% to -15%, 50/60 Hz
Overvoltage Category
III
SGDV
(Three Phase, 200 V)
R70 R90 1R6 2R8 3R8 5R5 7R6 120 180 200 330 470 550 590 780
Continuous Output Current
[Arms]
0.66 0.91 1.6
2.8
3.8
5.5
7.6 11.6 18.5 19.6 32.9 46.9 54.7 58.6 78.0
Instantaneous Max. Output
Current [Arms]
2.1
2.9
5.8
9.3 11.0 16.9 17
28
42
56
84
110 130 140 170
Regenerative Resistor
*
None or external
Built-in or external
External
Main Circuit Power Supply
Three-phase, 200 to 230 VAC, +10% to -15%, 50/60 Hz
Control Power Supply
Single-phase, 200 to 230 VAC, +10% to -15%, 50/60 Hz
Overvoltage Category
III