6 Utility Functions (Fn
)
6-22
(1) Preparation
There are no tasks that must be performed before the execution.
(2) Operating Procedure
Follow the steps to set enable or disable writing.
Setting values are as follows:
•
"
P.0000
"
: Write permitted (Releases write prohibited mode.) [Factory setting]
•
"
P.0001
"
: Write prohibited (Parameters become write prohibited from the next power ON.)
Note: To make the setting available, change the setting to P.0000 as shown in step 3.
Step
Display after Operation
Keys
Operation
1
Press the
Key to view the main menu for the
utility function.
Use the
or
Key to move through the list and
select Fn010.
2
Press the
Key. The display changes to the Fn010
execution display.
3
Press the
or
Key to select one of the follow-
ing settings.
P.0000: Write permitted [Factory setting]
P.0001: Write prohibited
4
Press the
Key. The setting value is written into
the SERVOPACK, and the status display changes as
follows: "BB" to "DONE" to "BB."
5
To enable the setting, turn the power supply to the SERVOPACK OFF and ON again.
B B
−
F U N C T I O N
−
F n 0 0 F : C u r M a n u A d j
F n 0 1 0 : P r m P r o t e c t
F n 0 1 1 : M o t o r I n f o
F n 0 1 2 : S o f t V e r
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 0
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1
B B
P a r a m e t e r
W r i t e P r o t e c t
P . 0 0 0 1